• DC Inverter Ground Source Heat Pump Manufacturer
  • DC Inverter Ground Source Heat Pump Manufacturer
  • DC Inverter Ground Source Heat Pump Manufacturer
  • DC Inverter Ground Source Heat Pump Manufacturer
  • DC Inverter Ground Source Heat Pump Manufacturer
  • DC Inverter Ground Source Heat Pump Manufacturer

DC Inverter Ground Source Heat Pump Manufacturer

Certification: ISO9001
Working Medium: Freon
Heat Source Type: Air Source Heat Pump
Type: Air Source, Water Source, Ground Source
Function: Heating Water
Ambient Temp. Range: -15degree+43degree
Samples:
US$ 2000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
SFXKR-017II
Compressor
Scroll Type
Transport Package
Wooden Box
Specification
See parameters
Trademark
Venttech
Origin
Shanghai
HS Code
8418612090
Production Capacity
50000PCS/Year

Product Description

Heat pump Details Images
DC Inverter Ground Source Heat Pump ManufacturerDC Inverter Ground Source Heat Pump ManufacturerDC Inverter Ground Source Heat Pump ManufacturerCommercial water heater heat pump series
MODEL KFXR-010UI KFXR-018UII KFXR-023UII KFXR-036UII KFXR-045UII KFXR-070UII KFXR-090UII
Heating mode   Circulating
Ambient temp. range ºC -15~+43ºC
Rated heating capacity KW 10 18 23 36 45 70 90
COP W/W 4.17 4.3 4 4.2 4.2 4.1 4.1
Rated power input KW 2.4 4.2 5.75 8.57 10.7 17 21.9
Max. running current A 17 14 16 24.8 30 45 58
Power supply / 220V 1N~50Hz 380v 3N~50Hz
IP code / IPX4
Safety function / High and low pressure protection, Overload protection, Temperature protection Power phase sequence protection, etc.
Refrigerant type/weight -/kg R407c/1.4 R407c/2.7 R407c/2.5 R407c/2.0*2 R407c/2.5*2 R407c/7.5*2 R407c/8.5*2
Compressor QTY PCS 1 1 1 2 2 2 2
Compressor type / Scroll
Max. temp. outlet water ºC 60
Water side heat exchanger type / Casing/high efficiency tank High efficiency tank Casing High efficiency tank
Air side heat exchanger type / Finned heat exchanger
Circulating waterpipe nozzle inch G3/4'' Internal thread G1'' Internal thread G1.2'' Internal thread G1.5'' Internal thread G1.5'' Internal thread DN100 DN100
Outlet nozzle inch G3/4'' Internal thread G1'' Internal thread G1.2'' Internal thread G1.5'' Internal thread G1.5'' Internal thread DN100 DN100
Circulating water flow inch 1.72 3.1 3.95 6.2 7.74 12.04 15.48
Air out type / Top discharge
Fan motor QTY PCS 1 1 1 2 2 2 2
Noise dB/(A) 56 56 57 59 65 69 72
Machine dimension (W×D×H) mm 750×690×870 750×690×1070 830×793×1084 1500×690×1070 1500×690×1270 2100×1100×2000 2100×1100×2000
Packing dimension (W×D×H) mm 800×740×1000 800×740×1200 900×930×1200 1550×740×1200 1550×740×1400 2140×1200×2040 2140×1200×2040
Net weight kg 110 130 150 290 350 700 800
Gross weight kg 130 150 170 330 390 750 860
Remarks:
1. Test conditions: (DB/WB) 20°C/15°C, inlet water temperature 15°C, outlet water temperature 55°C.
2. Due to product improvement, above datas are subject to change without prior notice, please take the rating plate as standard.


DC Inverter Ground Source Heat Pump ManufacturerGeothermal water to water heat pump series
Model SFXKR-017II SFXKR-032II SFXK-015II SFXK-040II
Ambient temp. range ºC -5~+25 -5~+25 -5~+25 -5~+25
Power Supply / 380V 3N~50Hz
Electric shock proof grade / Class I Class I Class I Class I
Protection grade / IPX4 IPX4 IPX4 IPX4
Floor heating capacity/COP KW/- 17/4.8 32/4.8 15/4.8 40/4.8
Rated heating capacity/COP KW/- 16/4.1 31/4.1 13.7/4.1 36.5/4.1
Rated cooling capacity/COP KW/- 15/5 28.5/5 13.0/5 34/5
Domestic Water heating capacity/COP KW/- 16.5/4.4 28.5/4.4 / /
Floor heating input power. KW 3.5 6.7 3.13 8.3
Rated heating input power KW 3.9 7.6 3.74 8.9
Rated cooling input power KW 3 5.7 2.6 6.8
Domestic water heating power KW 3.8 6.5 / /
Max. working current A 11.8 23 10 28
Refrigerant/weight -/kg R410a/2.5 R410a/2.5×2 R410a/2.5 R410a/4.0×2
Compressor Type / Scroll Scroll Scroll Scroll
Quantity PCS 1 2 1 2
Water yield L/h 1400 2600 1200 3200
Dimension (W×D×H) mm 745×650×960 1400×750×960 745×650×960 1400×750×960
Packing dimension(W×D×H) mm 805×700×1020 1460×810×1020 805×700×1020 1460×810×1020
Heat exchanger Heat source side Type / Plate heat exchanger or Tube in shell heat exchanger
Max/low outlet temperature ºC +25~-5 (Antifreeze solution with 25% ethylene glycol)
Water inlet size inch G1''A internal thread G1 1/2'' internal thread G1 internal thread DN40
Water flow volume m³/h 1.4 2.6 1.2 3.2
Water pressure loss(Max.) kPa ≤25 ≤30 ≤30 ≤30
Use side Type / plate heat exchanger or Tube in shell heat exchanger
Maximum/low outlet temperature ºC 58/5 58/5 58/5 58/5
Nozzle size inch G1''A internal thread G1 1/2'' internal thread G1 DN40

Domestic water side
Type / High-efficiency tank heat exchanger
Maximum/low outlet temperature ºC 60 60 60 60
Rate Flow m³/h 2.84 4.9 2.4 6.5
Nozzle size inch G1'' internal thread G1 1/2'' internal thread G1'' internal thread G1 1/2'' internal thread
a: Floor heating condition:Heat source side inlet temperature 0 ºC and use side inlet water temperature 30 ºC;
b: Rated heating condition:Heat source side inlet temperature 0 ºC and use side inlet water temperature 30ºC;
c: Rated cooling condition:Heat source side inletwater temperature is 25ºC and outlet water temperature is 30ºC; use side inlet water temperature is 12ºC and outlet water temperature is 7ºC.
*Due to product improvement, above datas are subject to change without prior notice, please take the nameplate as standard. 


Product Testing
DC Inverter Ground Source Heat Pump ManufacturerDC Inverter Ground Source Heat Pump ManufacturerDC Inverter Ground Source Heat Pump Manufacturer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001
OEM/ODM Availability
Yes