2024China Self Contained Marine Air Conditioner

Product Details
Customization: Available
After-sales Service: on Line
Warranty: 1 Year
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • 2024China Self Contained Marine Air Conditioner
  • 2024China Self Contained Marine Air Conditioner
  • 2024China Self Contained Marine Air Conditioner
  • 2024China Self Contained Marine Air Conditioner
  • 2024China Self Contained Marine Air Conditioner
  • 2024China Self Contained Marine Air Conditioner
Find Similar Products

Basic Info.

Model NO.
Customized
Type
Cabinet Air Conditioner
Air Tube Material
Galvanized Sheet
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Ultra Quiet
Application Fields
Marine
Mounting
Floor Standing
Lifetime
5~10 years
Certification
ISO
Condition
New
Transport Package
Plywood Box
Specification
1*1*1
Trademark
Venttk
Origin
Shanghai, China(Mainland)
HS Code
8418612090
Production Capacity
5000 Unit Per Month

Product Description

This self-contained unit, has standard stainless steel, using rivet stainless steel metal structure, and nickel-copper coaxis tube as heat exchanger for sea water side. The fan duct can be roted as required when you install it.The fan blower has advantage such as high static pressure, big air flow and low noise. This self-contained unit has the maximum compact design and better performance. As customer required, we can also provide D-smart control PCB with soft-start function to minimize the starting current.
Self-contained Unit
Model MS6-E2C MS9-E2C MS12-E2C MS16-E2C
Power supply Ph-V-Hz 1Ph/220V/50Hz
Cooling Capacity BTU 6,000 9,000 12,000 16,000
Input power W 430 720 980 1,210
Rated current A 2.0 3.3 4.5 5.5
EER   4.1 3.7 3.6 3.9
Heating Capacity BTU 6,500 10,000 13,300 17,700
Input power W 450 770 1,000 1,270
Rated current A 2.1 3.5 4.6 5.8
COP   4.2 3.8 3.7 4.0
Max.current A 3.0 5.3 6.8 8.2
Sea water flow M3/h 0.42 0.64 0.85 1.15
Indoor air flow M3/h 250 630 630 810
Dehumidification capacity L/h 0.7 1.1 1.8 2.1
Noise level dB(A) ≤45 ≤50 ≤50 ≤54
Dimension(L*W*H) mm 461X265X283 602X375X387 601X398X388 627X400X433
Control box(L*W*H) mm 263X182X95
Net weight Kg 18 27 30 38
Refrigerant type   R410a
Fan duct size mm Φ100 Φ150
Sea water pipe mm G1/2"-16
Condensed water pipe Mm G1/2"-19
Note: A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced
 
Model MS24-E2C MS32-E2C MS36-E2C MS30-S1C MS36-S1C
Power supply Ph-V-Hz 1Ph/220V/50Hz 3Ph/380V/50Hz
Cooling Capacity BTU 24,000 32,000 36,000 30,000 36,000
Input power W 1,720 2,400 2,760 2,420 2,620
Rated current A 7.8 11 12.6 4.9 5.2
EER   4.1 3.9 3.8 3.6 4.0
Heating Capacity BTU 27,500 38,400 43,900 36,300 44,300
Input power W 1,920 2,830 3,300 2,720 3,120
Rated current A 8.7 12.8 15 5.2 5.8
COP   4.2 4.0 3.9 3.9 4.2
Max.current A 11.7 18 20.2 5.9 6.3
Sea water flow M3/h 1.7 2.3 2.5 2.1 2.5
Indoor air flow M3/h 1,150 1,800 1,800 1,850 1,850
Dehumidification capacity L/h 3.1 4.5 4.9 4.2 4.9
Noise level dB(A) ≤59 ≤64 ≤67 ≤65 ≤67
Dimension(L*W*H) mm 707X433X488 756X481X560 762X511X560 755X480X560 760X510X550
Control box(L*W*H) mm 410X195X115 400X195X105
Net weight Kg 56 66 88 65 87
Refrigerant type   R410a R22
Fan duct size mm Φ150 Φ200
Sea water pipe mm G3/4"-19 G1"-25
Condensed water pipe Mm G3/4"-25
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced


This marine modular chillers are ther most flexible, compact design, and light-weight machines. They are the most reliable and easy-service chiller system for marine use. The single chiller capacity from 36,000 to 180,000btu. Generally it can be combined from 1 to 6 untis to a system with manifold piping system. Our control system can automatic run the units according to the heat load of the indoor fan coil unit. So that it can reduce the energy consumption. This system is widely used for catamaran fast-speed ferry boats. Thanks to the single chillers combining together, this system can back up each other, and provide the most reliable chiller function to the boat.
Single chiller has scroll compressor, 4-way valve, coaxis tube condenser, shell& tube evaporator, high/low pressure valve, pressure gauge, drain-pan combine to a compact&light weight system.
T series has knuring titanium coaxis tube for sea water heat exchanger, good for heavy duty chiller systerm in the real sea water use.


Modular water chiller

Single-compress chiller unit
Model MWA36-S2C/T MWA48-S2C/T MWA60-S2C/T MWA72-S2C/T
Power supply Ph-V-Hz 3Ph/380V/50Hz
Cooling Capacity BTU 36,000 48,000 60,000 72,000
Input power W 2,600 3,460 4,480 5,200
Rated current A 4.6 6.2 8.0 9.2
EER   4.0 4.0 3.9 4.0
Heating Capacity BTU 44,500 59,300 75,000 89,000
Input power W 3,250 4,330 5,780 6,500
Rated current A 5.7 7.6 10.3 11.4
COP   4.0 4.0 3.8 4.0
Max.current A 7.4 9.9 13.6 14.8
Sea water flow M3/h 2.8 3.7 4.7 5.6
Chilled water flow M3/h 2.3 3.1 3.8 4.6
Sea water pipe   G1" inner thread
Chilled water pipe   G1" inner thread
Condensed water pipe Mm G3/4"-25
Noise level dB(A) ≤52 ≤55 ≤62 ≤65
Dimension(L*W*H) mm 692X440X535 888X415X540 888X450X540
Net weight Kg 84 90 101 107
Refrigerant type   R410a
 
Model MWA90-S2C/T MWA120-S2C/T MWA150-S2C/T MWA180-S2C/T
Power supply Ph-V-Hz 3Ph/380V/50Hz
Cooling Capacity BTU 90,000 120,000 150,000 180,000
Input power W 6,230 9,030 10,360 12,430
Rated current A 11.8 16.4 19.5 23.4
EER   4.0 3.9 4.2 4.2
Heating Capacity BTU 115,000 158,000 189,800 227,700
Input power W 7,500 11,300 12,940 15,530
Rated current A 13.5 19.6 23 27.6
COP   4.5 4.0 4.3 4.3
Max.current A 15.4 23.8 29 34.8
Sea water flow M3/h 7.3 9.3 11.6 14
Chilled water flow M3/h 5.5 7.6 9.5 11.4
Sea water pipe   G1" inner thread
Chilled water pipe   G1" inner thread
Condensed water pipe Mm G3/4"-25
Noise level dB(A) ≤67 ≤71 ≤74 ≤78
Dimension(L*W*H) mm 910X600X650 1150X650X820
Net weight Kg 135 158 215 255
Refrigerant type   R410a




Floored Fan Coil Unit
Model   MF9-E5A MF12-E5A MF18-E5A MF24-E5A MF36-E5A
Power supply Ph-V-Hz 1Ph/220V/50Hz
Cooling capacity BTU 9,000 12,000 18,000 24,000 36,000
Heating capacity BTU 10,000 13,100 19,800 26,700 42,000
Max. input power W 140 140 200 360 680
Water flow M3/h 0.55 0.77 1.1 1.5 2.2
Air flow M3/h 630 630 810 1,150 1,800
Water pipe mm G3/4"-25
Condensed water pipe mm G3/4"-25
Fan duct size mm Φ150 Φ200
Noise level dB(A) ≤50 ≤50 ≤54 ≤59 ≤67
Net weight Kg 13.5 14 18 25 33
Dimension(L*W*H) mm 512X360X390 512X360X440 560X380X485 580X440X583




Horizontal Fan Coil Unit
Model   MF9-E5B MF12-E5B MF18-E5B MF24-E5B MF36-E5B MF48-E5B
Power supply Ph-V-Hz   1Ph/220V/50Hz
Cooling capacity BTU 9,000 12,000 18,000 24,000 36,000 48,000
Heating capacity BTU 10,300 13,800 20,700 27,600 41,400 55,200
Max. input power W 57 72 108 150 215 253
Water flow M3/h 0.55 0.77 1.1 1.5 2.2 3.0
Air flow M3/h 510 680 1,020 1,360 2,040 2,380
Wind pressure Pa 30
Water pipe mm G3/4"-25
Condensed water pipe mm G3/4" external thread
Noise level dB(A) ≤42 ≤44 ≤45 ≤49 ≤54 ≤55
Net weight Kg 12 14 16 25 31 37
Dimension(L*W*H) mm 815X465X230 915X465X230 1095X465X230 1425X465X230 1725X465X230 1985X465X230




Ceiling Cassette Fan Coil Unit
Model   MF18-E5E MF24-E5E MF36-E5E MF48-E5E
Power supply Ph-V-Hz   1Ph/220V/50Hz
Cooling capacity BTU 18,000 24,000 36,000 48,000
Heating capacity BTU 22,000 36,000 56,000 66,000
Max. input power W 76 132 189 220
Water flow M3/h 1.1 1.5 2.2 3.0
Air flow M3/h 850 1,400 2,040 2,380
Water pipe mm G3/4"-25
Condensed water pipe mm Φ25
Noise level dB(A) ≤43 ≤48 ≤50 ≤52
Net weight Kg 21 26 34 34
Body dimension(L*W*H) mm 710X710X290 832X832X290
Panel dimension(L*W*H) mm 830X830X30 980X980X30




DC compressor, DC fan blower, good for boat without marine generator. DC voltage: 12V/48V/48V
DC Unit
Model MS3.5-A3A MS3.5-B3A MS7-B3A MS7-C3A MS11-C3A
Power supply Ph-V-Hz DC12V DC24V DC24V DC48V DC48V
Cooling Capacity BTU 3,500 3,500 7,000 7,000 11,000
Input power W 295 296 560 560 850
Rated current A 26 13 26 26 20
EER   3.5 3.5 3.8 3.8 3.6
Heating Capacity BTU 4,000 4,000 7,500 7,500 12,000
Input power W 310 310 540 540 890
Rated current A 27 13.5 25 25 22
COP   3.8 3.8 4.0 4.0 4.0
Max.current A 31 16 28 28 24
Sea water flow M3/h 0.35 0.45 0.46 0.46 0.75
Indoor air flow M3/h 250 250 290 290 760
Dehumidification capacity L/h 0.6 0.6 0.7 0.7 1.6
Noise level dB(A) ≤55 ≤55 ≤55 ≤55 ≤58
Dimension(L*W*H) mm 490X236X282 484X236X318 598X365X346
Control box(L*W*H) mm 252X212X125 262X222X125
Net weight Kg 20 20 25 25 36
Refrigerant type   R134a
Fan duct size mm Φ100 Φ100 Φ100 Φ100 Φ150
Sea water pipe mm Φ19
Condensed water pipe Mm G1/2"-19


The split marine air conditioner consists of two parts: the outdoor unit and the indoor unit. The indoor unit is light and low in noise. The fan can be installed in a 90-degree rotation according to the cabin conditions. The units use stainless steel sheet metal, corrosion-resistant and high-efficiency nickel-copper heat exchangers, and soft starters can be configured according to customer needs to reduce the current and voltage fluctuations of air conditioning startup.
()Split Type Conedensing Unit(Outdoor Unit)
Model MC9-E2A MC12-E2A MC18-E2A MC24-E2A MC36-S2A/T MC72-S2A/T
Power supply Ph-V-Hz 1Ph/220V/50Hz 3Ph/380V/50Hz
Cooling Capacity BTU 9,000 12,000 18,000 24,000 36,000 48,000
Input power W 620 840 1,060 1,260 2,600 4,300
Rated current A 3.3 4.5 6.0 7.8 5.5 8.0
EER   4.2 4.1 4.1 4.1 4.0 4.0
Heating Capacity BTU 10,000 13,000 19,900 27,300 44,500 75,000
Input power W 630 860 1,100 1,560 3,200 5,780
Rated current A 3.5 4.6 6.6 8.7 6.3 9.5
COP   4.4 3.8 4.0 4.2 4.0 4.1
Max. current A 4.8 6.3 9.0 10.2 7.6 12.2
Sea water flow M3/h 0.64 0.85 1.2 1.7 2.8 4.7
Sea water pipe mm G1/2"-16 G3/4"-25 G1" inner grooved
Refrigerant type   R410a
Connecting pipe   1/4",3/8" 1/2",3/8" 5/8",3/8" 5/8",3/8" 5/8",3/8" 7/8",3/8"
Dimension(L*W*H) mm 397X323X347 397X315X387 462X322X410 472X322X450 664X436X495 662X436X490
Net weight Kg 13 15 19 27 67 81
Noise level dB(A) ≤50 ≤50 ≤50 ≤50 ≤55 ≤55
Condensed water pipe mm G1/2"-19 G3/4"-25
Note: A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced


Split Type Indoor Unit
Fan blower can be rotated, stainless steel sheet metal, double drain pan with spill-proof design
Floored Indoor Unit
 
Floored Indoor Unit
Model MA9-E2A MA12-E2A MA18-E2A MA24-E2A MA36-E2A
Power supply Ph-V-Hz 1Ph/220V/50Hz
Cooling capacity BTU 9,000 12,000 18,000 24,000 36,000
Heating capacity BTU 10,000 13,300 20,100 27,500 43,900
Input power W 140 140 200 360 680
Refrigerant type   R410a
Connecting pipe   1/4",3/8" 1/2",3/8" 5/8",3/8" 5/8",3/8" 5/8",3/8"
Dimension(L*W*H) mm 540X360X390 540X350X390 540X360X425 585X380X485 1035X365X405
Indoor airflow M3/h 630 630 810 1,150 1,260
Noise level dB(A) ≤52 ≤52 ≤54 ≤59 ≤67
Net weight Kg 14 15 19 25 30.5
Fan duct size mm Φ150
Condensed water pipe Mm G3/4"-25
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced



Low profile and special double drain pan with spill-proof design, no condensing water leaking, low noise.
Horizontal Indoor Unit
Elegant design, fan blow louver adjustable and moveable. Drain pan produced by one piece molding process. duo-drain pump to make sure the condensing water no spill out.
Ceiling Cassette Indoor Unit
 
  Horizontal Indoor Unit Ceiling Cassette Indoor Unit
Model MA18-E2B MA24-E2B MA36-E2B MA24-E2E MA36-E2E
Power supply Ph-V-Hz 1Ph/220V/50Hz
Cooling capacity BTU 18,000 24,000 36,000 24,000 36,000
Heating capacity BTU 20,700 27,600 41,400 27,300 42,300
Input power W 108 150 215 132 189
Refrigerant type   R410a
Connecting pipe   5/8",3/8"
Indoor airflow M3/h 1,020 1,360 2,040 1,400 2,040
Noise level dB(A) ≤45 ≤49 ≤54 ≤48 ≤50
Net weight Kg 17.2 26 31.4 26 34
Body dimension(L*W*H) mm 1095X465X230 1425X465X230 1725X465X230 710X710X290 832X832X290
Panel dimension(L*W*H)   / / / 830X830X30 980X980X30
Condensed water pipe Mm G3/4" external thread
Note:A 90 degree turn of the air supply hose will reduce the air volume by more than 25%. When installing, the air pipe should be shortened as much as possible, and the right-angle turn of the air pipe or air duct should be reduced
 
2024China Self Contained Marine Air Conditioner2024China Self Contained Marine Air Conditioner2024China Self Contained Marine Air Conditioner2024China Self Contained Marine Air Conditioner2024China Self Contained Marine Air Conditioner2024China Self Contained Marine Air Conditioner
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier