• Subsidiary Agriculture Food Vegetable Heat Pump Dryer
  • Subsidiary Agriculture Food Vegetable Heat Pump Dryer
  • Subsidiary Agriculture Food Vegetable Heat Pump Dryer
  • Subsidiary Agriculture Food Vegetable Heat Pump Dryer
  • Subsidiary Agriculture Food Vegetable Heat Pump Dryer
  • Subsidiary Agriculture Food Vegetable Heat Pump Dryer

Subsidiary Agriculture Food Vegetable Heat Pump Dryer

Certification: RoHS, CE
Working Medium: Freon
Heat Source Type: Ground Source Heat Pump (GSHP)
Compressor: Copreland Compressor
Electrical Components: Schneider
Special Function: Automatically Defrosting
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
D4-012-3X350
Control
Micro Processor Controller with LCD Desplay
Transport Package
Plywood Box
Trademark
Venttech
Origin
Shanghai

Product Description

Heat pump dryer series
Outdoor machine KFXH-013UAII KFXH-013SAII KFXH-016UAII KFXH-016SAII KFXH-026UAII KFXH-026SAII KFXH-032UAII KFXH-032SAII KFXH-060SAII
Ambient temp.range ºC -7~43ºC -7~43ºC -7~43ºC -7~43ºC -7~43ºC -7~43ºC -7~43ºC -7~43ºC -7~43ºC
Rated heating capacity kw 13 13 16 16 26 26 32 32 32
Rated input power kw 4.33 4.33 5.33 5.33 8.67 8.67 10.67 10.67 10.67
Max. working current A 12 12 14 14 25 25 30 30 30
Power supply / 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz 380V 3N~50Hz
Protection grade / IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Safety function / High and low pressure protection,Overload protection,
 Temperature protection Power phase sequence protection
High and low pressure protection,Overload protection,
 Temperature protection Power phase sequence protection
High and low pressure protection,Overload protection,
 Temperature protection Power phase sequence protection
High and low pressure protection,Overload protection,
 Temperature protection Power phase sequence protection
High and low pressure protection,Overload protection,
 Temperature protection Power phase sequence protection
High and low pressure protection,Overload protection,
 Temperature protection Power phase sequence protection
High and low pressure protection,Overload protection,
 Temperature protection Power phase sequence protection
High and low pressure protection,Overload protection,
 Temperature protection Power phase sequence protection
High and low pressure protection,Overload protection,
 Temperature protection Power phase sequence protection
Refrigerant type/Weight -/kg R134a/4 R134a/4 R134a/4.5 R134a/4.5 R134a/4×2 R134a/4×2 R134a/5×2 R134a/5×2 R134a/5×2
Compressor quantity PCS 1 1 1 1 2 2 2 2 2
Compressor type / Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll
heat exchanger type / Finned heat exchanger Finned heat exchanger Finned heat exchanger
Connecting pipe spec. inch 3/8",5/8" 3/8",5/8" 3/8",5/8" 3/8",5/8"×2 3/8",5/8"×2 3/8",5/8"×2 3/8",5/8"×2 3/8",5/8"×2 3/8",5/8"×2
Air out type / Top discharge Sideward Top discharge Sideward Top discharge Sideward Top discharge Sideward Sideward
Fan motor QTY PCS 1 1 1 1 2 2 2 2 2
Noise dB/(A) 65 65 66 66 68 65 68 65 65
machine dimension (width×depth×high) mm 750×690×1070 1080×1040×1100 750×690×1070 1080×1040×1100 1500×690×1070 1720×1060×1100 1500×690×1270 1720×1060×1100 1720×1060×1100
Packing dimension(width×depth×high) mm 800×740×1170 1150×1100×1200 800×740×1170 1150×1100×1200 1550×740×1170 1800×1110×1200 1550×740×1370 1800×1110×1200 1800×1110×1200
Net weight kg 130 130 140 140 230 230 300 300 300
Gross weight kg 140 140 150 150 250 250 330 330 330
Indoor machine KFXH-013UAII KFXH-013SAII KFXH-016UAII KFXH-016SAII KFXH-026UAII KFXH-026SAII KFXH-032UAII KFXH-032SAII KFXH-032SAII
Power supply / 220V 1N~50Hz 220V 1N~50Hz 220V 1N~50Hz 220V 1N~50Hz 220V 1N~50Hz 220V 1N~50Hz 220V 1N~50Hz 220V 1N~50Hz 220V 1N~50Hz
heat exchanger type / Finned heat exchanger Finned heat exchanger Finned heat exchanger
Max. air outlet temp. ºC 75 75 75 75 75 75 75 75 75
Circulating air volume m³/h Customizable according to customer needed Customizable according to customer needed Customizable according to customer needed
machine dimension (width×depth×high) mm
Packing dimension(width×depth×high) mm
Net weight kg
Gross weight kg
Remarks:
1.Test conditions: (DB/WB) 20°C/15°C, return air temperature 55°C, air outlet temperature 60°C.
2.Due to product improvement, above datas are subject to change without prior notice, please take the nameplate as standard.
Subsidiary Agriculture Food Vegetable Heat Pump DryerSubsidiary Agriculture Food Vegetable Heat Pump DryerSubsidiary Agriculture Food Vegetable Heat Pump DryerSubsidiary Agriculture Food Vegetable Heat Pump DryerSubsidiary Agriculture Food Vegetable Heat Pump Dryer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001
OEM/ODM Availability
Yes