Top Quality Air Cooled Condenser with Competitive Price

Condensation Forms: Air-Cooled
Refrigerant: CHF2Cl
Type: Air Cooled Condenser
Material: Copper
Structural Form: Horizontal
Heat Transfer Mode: Regenerative
Samples:
US$ 2500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
SHSL-D2-601-14X630F29
Form
Sheet
Application Field
Cooing
Certification
RoHS, ISO
Condition
New
Product Name
Top Quality Air Cooled Condenser with Competitive
Cooling Capacity
23kw
Air Flow
8137CMH
Surface
73m2
Power Supply
380V-3pH-50Hz
Total Motor Power
0.83kw
Total Current
1.45A
Dry Weight
75kg
Design Pressure
2.0MPa
Testing Pressure
2.5MPa
Transport Package
Wrap Film/Pallet
Specification
refrigerant unit
Trademark
VENTTK
Origin
China
HS Code
8415901000
Production Capacity
100units/Month

Product Description

Top quality air cooled condenser with competitive price 
Dry Coolers are widely used in refrigeration, air-conditioning, food processing, heating plants and power plants.

General productions:
Suitable environment
Dry Cooler series:D1 and D2 series.
Environment temperature:  35ºC.
Air does not contain chemical substances, corrosive gasses and dust-free;
Please specify requirements for explosion-proof upon order
Design Conditions:   Design pressure 2.0MPa; Test pressure 2.5MPa                
Medium: WATER    
Working conditions:
Environment Specifications
Ambient Temperature 35ºC,                                  Inlet Temperature 48 ºC,Outlet Temperature 39 ºC     D4 Series
 
Details:
Sign Name Function
A Stand Fix equipment
B MetalSheet Casing Galvanized Steel Coated Casing
C Cooling Coil Al Fin and Copper Tube
D Fan Low Energy consumption fan to maximize air flow and low noise
 
Drycooler  
Capacity:15KW Medium: ethylene glycol 34 vol%
Surface reserve:5.7% Inlet:45ºC
airflow:5810m³/h outlet:40ºC
airinlet:32ºC presure drop:0.52bar
altitude:1500m volume flow:2.79m³/h
Fans(AC): 1piece3~400V50Hz Noise pressure level:42dB(A)
data per motor(nominal data): at a distance of:10m
speed:1180min-1/1350min-1 Noise power level:73dB(A)
capacity(el) 0.55kw E
current:0.90A  
total el power consumption:0.45KW energy sfficiency class:E(2014)
casing:Galv.sheet.RAL 7035 Tube: copper
surface:82m2 fins:aluminum
tube volume:10.81 connections per unit:
fin spacing:2.4mm inlet:28*1.5mm
dry weight:96kg outlet:28*1.5mm
Max.operation pressure:16bar PED classification:Art.3.par.3
   


Site assessment
Selected installation site must meet the following requirements:
Level Ground;
Ground or Floor strength able to support the wedight of equipment;
no obstructions at air outlet.
Upon confirming above conditions, take the following installation steps. Forklift or lifting product out of wooden pallets, loosen transport screw at stand and tighten after raising the screws to same horizontal plane as product. After moving product to the predetermined location, bolt tightly with large washer and spring washer.
 

Warning
Minimize bias and ensure the level of the product during installation.
Ensure tubes level and no loosen parts in dry cooler
During installation, avoid weight of pipeline on the dry coolers.  
 
 Wiring
Power requirements:       
Axial Fan power wiring: Axial fans are often using one phase or 3 phase motor. The 3 phase motor has two configuration, Y-shape and △Shape
Fan motor should have reliable power supply equipped with over voltage, under voltage and over current protection. Each fan is equipped with current protection settings. Internal thermal protection devise should be connected to the control lines to prevent damage to the motor due to over voltage, under voltage, lack of phase, contact failure. Motor wiring shall be installed according to the requirements when using two-speed motor.
 
warning
 
Motor overcurrent protection and built in thermal protection settings must be connected.
Electrical connections must be completed by qualified professionals
Ensure wiring are correct and accurate to prevent motor failure
 
Electrical Installation
 
Warning
 
Equipment installation must be done by qualified personnel
Ensure all electrical circuits are installed in accordance GB 8877-88(household appliances installation, use, maintenance and safety requirements) or any other local regulations
Equipment shall be safely grounded with resistance less than 2Ω
Ensure all fan connecting cables are according to required standards of fan manufacturers.
 
Equipment commissioning
4.1  power on check
Check to ensure all requirements above are met. All requirements is to be met before trial run. Ensure all accessories are installed securely before powering on.
 
4.2  Power supply check
Ensure voltage and power supply matches name plate by measuring equipment and is safely grounded with less than 2ohm before power up.
 
4.3  Trial Operation
Ensure each fan is tighten and is not obstructed prior to commissioning. Rotation of the motor must be accordance with the factory specification. Ensure no jamming and free rotation to fan and motor. 

Photos show:








 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001
OEM/ODM Availability
Yes