Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)

Shanghai Venttech Refrigeration Equipment Co., Ltd.
  • Audited Supplier
  • 10 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Modular Design: Can be expanded according to specific demand requirements.
  • Customizable Protocol: Standard communication protocol available; special format monitoring protocols can be customized.
  • Dual Power Backup: Optional dual power supply backup ensures system reliability.
  • Frequency Conversion Pump: Optional double back-up high-efficiency pump adjusts flow rate automatically based on load.
  • Corrosion Resistant Material: Constructed with 304 stainless steel and above materials for durability.
  • Comprehensive Monitoring: Includes temperature, flow, pressure, conductivity, turbidity, hardness, and pH monitoring.
  • Factory Pre-tested: Pre-installed and tested at the factory to reduce on-site workload.
  • Ultra-Quiet Operation: Features ultra-quiet motor with low noise and long service life.

Product Images of Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)

Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC) pictures & photos
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC) pictures & photos
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC) pictures & photos
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC) pictures & photos
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC) pictures & photos
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC) pictures & photos
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
  • Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
  • Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
    Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
  • Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
    Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
  • Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
    Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
  • Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
    Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
  • Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
    Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
  • Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
    Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)

Find Similar Products

Product Description

Product Description

 

Coolant Distribution Unit (CDU)
 

Product descriptions from the supplier

 

Coolant Dustribution Unit

 

Product Description

 Description

The Coolant Distribution Unit (CDU) is the central component of the water cooling system, responsible for efficiently distributing the cooling medium to meet the cooling needs of various applications. It ensures the system operates stably by incorporating additional monitoring and support devices. The CDU on the secondary side of the heat exchange unit is primarily used for controlling heat exchange in liquid cooling heat sink systems. This system includes a frequency conversion circulating pump, plate heat exchanger, electric control valve, temperature sensor, pressure sensor, filter, expansion tank, flow meter, and online liquid replenishment function. It is pre-installed and tested at the factory to reduce on-site workloads.

 

Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)

 

Performance range

· Heat transfer quantity:350~1500kW
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)

 

Model   CDU020W-080W 

Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
Features

· 10-inch touch screen, multi-level authority control;

· Modular design, can be increased according to the demand;

· (Optional) Double back-up high-efficiency frequency conversion pump automatically adjusts the flow rate according to the loaded condition;

· (Optional) Dual power supply backup;

· Corrosion-resistant 304 stainless steel and above material piping components;

· Standard Venttk liquid-cooled data center function control system, temperature monitoring, secondary side temperature control, flow and differential pressure control, anti-condensation protection, conductivity monitoring (optional), water turbidity monitoring (optional), water hardness monitoring (optional), PH value monitoring (optional);

· Ultra-quiet motor, low noise, long service life;

· Standard Modbus TCP communication protocol, rich detection, alarm and protection functions in the system, automatic protection of the setup parameters, power-down will not lose the operating parameters and alarm records;

· Provide standard communication protocol, can be customized according to customer demand for special format monitoring protocol;

· Secondary side filtration precision: 25~100 (μm) ultra-wide design range.

 

 

Our Advantages
    With Venttk's cutting-edge design, the CDU enhances the efficiency and dependability of the water cooling system. It boasts six channels that link the main pipeline to the secondary water separator of the water-cooled cabinet, eliminating installation and production errors with the use of clamps and rubber hoses.

    Venttk's CDU features a multi-stage centrifugal pump for circulating industrial water, ensuring a smooth and reliable flow of coolant. An expansion tank is integrated into the CDU to compensate for temperature fluctuations, maintaining consistent pressure levels and ensuring the system's reliable operation.

    To prevent issues like oxidation corrosion, inadequate circulation, and cavitation of the circulation pump, Venttk's CDU includes an automatic air vent valve on the top of the makeup water tank/main pipeline. This valve promptly eliminates non-condensable gases from the system.

    Furthermore, Venttk's CDU is equipped with a 150μm filter in its main path to preserve the quality of the coolant, guaranteeing the steady and secure operation of the entire system.

 

 
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
 
Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)Coolant Distribution Unit (CDU) for High-Performance Computing (HPC)
 
 
 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2241984". Items marked "verified" are certified.

Watch Video
Watch Video
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.

About Our Factory & Business Background

Address
Room 1801, Building 1, Lane 1100, Lanzhou Road, Yangpu District, Shanghai, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, EXW, Others
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month
Nearest Port
SHANGHAI, GUANGZHOU, QINGDAO

Our Production Capability & Technical Expertise

Main Products
Air Conditioning, Refrigeration Unit, Chiller, Condenser Units, Plate Heat Exchanger, Dry Cooler, Air Cooler, Condenser, Evaporator, Shell and Tube Heat Exchanger

Our Industry Experience & Global Business Record

Export Year
2009-01-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the warranty period?
We provide a 1-year warranty for this product.
What is the heat transfer capacity range?
The heat transfer quantity ranges from 350kW to 1500kW.
Can the communication protocol be customized?
Yes, we provide a standard protocol and can customize special format monitoring protocols according to customer demand.
What materials are used for the piping components?
The piping components are made of corrosion-resistant 304 stainless steel or higher grade materials.
Is the unit pre-installed and tested?
Yes, the unit is pre-installed and tested at the factory to reduce on-site workloads.
What is the filtration precision for the secondary side?
The secondary side filtration precision has an ultra-wide design range of 25 to 100 micrometers.
What is the lead time for production?
The lead time is one month during off-peak season and 1-3 months during peak season.
What payment terms are accepted?
We accept LC, T/T, PayPal, and Western Union.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now