Features
What's Immersion Liquid Cooling?
Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.
Why many large data centers have already moved or are considering the move to immersion cooling?
1. Up to 25% increase in power efficiency
2. Up to 80% cost reduction
3. Up to 60% hashrate increase
4. 50%+ equipment lifespan.
Working Diagram:
Our system suitable for different coolants, including BC888, dielectric fluid, Shell S3X, S5X, etc.
Our system suitable for Asic miners cooling system.
Recommended products:
For Cryptocurrency mining farm, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.
Air discharge direction |
|
Performance ranges |
Cooling capacity: from 148 to 921 kw
Air volume: from 76459 to 351663 m3/h
Sound pressure level: from 64 to 73 dB A(10m)
Dry coolers:customized on demand |
High efficiency heat exchanger |
Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.
Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).
Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
Fan |
Only choose low specific energy consumption fans.
Fan nozzle designs for maximum air flow and air throw.
Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.
Motor: protection class IP 54 and insulation class F.
Voltage:400V/3N/50Hz
Air separator for each fan. |
Testing |
Heat exchangers are supplied clean and tested at a pressure of 30 bars |
Options |
Coil design refrigerant: water, oil, glycol,BC-888.
Multiple circuits.
Sub-cooling circuits.
Stainless steel or aluminum casing.
Coated aluminum or copper fins.
Explosion ploof motor.
Customized fin spacing.
|
Product Parameters
Dry Cooler Feature.
BC888 bit mining cooling system Dry cooler use for bitcoin center
• Unique floating coil design avoids leakage caused by thermal expansion and contraction.
• Staggered fin pattern design and corrugated fin enhance air flow turbulence
• Inner-grooved copper tube increase heat transfer area and enhance heat transfer
• Optimized flow pass design ensure fully heat exchange with refrigerant
• Equipped with 2nd generation owl-wing fan motor as standard. It features with low noise level, large volume flow and low energy consumption. Ready for dual speed connection.
• Outdoor type powder coated casing made of galvanized sheet metal and stainless steel bolts provide a high resistance to corrosion.
• Optional features:
§ EC variable speed fan motor, to save great energy
§ ZAplus/AxiTop for greater volume flow and extreme silence
§ Adiabatic system significantly reduce energy consumption in summer
§ Epoxy coated or hydrophilic aluminum fin suitable for coastal or high corrosion area
§ Fluid dry cooler
§ Clean stainless steel tube and aluminum fin coil for cooling deionized water.
Dry cooler -- D1 series |
Model |
Unit |
D1-005-1X350 |
D1-006-1X350 |
D1-007-1X350 |
Capacity(water) |
Kw |
4.89 |
5.90 |
6.83 |
Capacity (20% Glycol) |
Kw |
4.72 |
5.69 |
6.69 |
Water flow |
m³/h |
0.85 |
1.03 |
1.20 |
Pressure Drop |
kPa |
36.00 |
31.00 |
58.00 |
Air volume |
m³/h |
2828 |
2712 |
2492 |
Fan |
Qty x Φ |
1XΦ350 |
1xΦ350 |
1xΦ350 |
Noise level |
dB(A) 10m |
31 |
31 |
31 |
Dimension(L*W*H) |
mm |
870*525*797 |
870*525*797 |
870*525*797 |