Coolant Distribution Unit (CDU) for High-Density Server Cooling

Shanghai Venttech Refrigeration Equipment Co., Ltd.
  • Audited Supplier
  • 10 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Customizable Liquid Flow Rate: Liquid flow rate is fully customized to meet specific cooling requirements.
  • Modular Design Scalability: Modular design allows capacity expansion according to increasing demand.
  • Advanced Monitoring System: 10-inch touch screen with multi-level authority control and real-time monitoring.
  • High-Efficiency Pump Options: Optional double-backup high-efficiency frequency conversion pumps for stable flow.
  • Corrosion-Resistant Materials: Constructed with 304 stainless steel and above for durable, corrosion-resistant piping.
  • Pre-installed & Tested: Factory pre-installed and tested to significantly reduce on-site installation workload.
  • Wide Filtration Precision: Secondary side filtration precision ranges from 25 to 100 microns for pure coolant.
  • Standard Communication Protocol: Supports Modbus TCP with customizable special format monitoring protocols.

Product Images of Coolant Distribution Unit (CDU) for High-Density Server Cooling

Coolant Distribution Unit (CDU) for High-Density Server Cooling
Coolant Distribution Unit (CDU) for High-Density Server Cooling pictures & photos
Coolant Distribution Unit (CDU) for High-Density Server Cooling
Coolant Distribution Unit (CDU) for High-Density Server Cooling pictures & photos
Coolant Distribution Unit (CDU) for High-Density Server Cooling
Coolant Distribution Unit (CDU) for High-Density Server Cooling pictures & photos
Coolant Distribution Unit (CDU) for High-Density Server Cooling
Coolant Distribution Unit (CDU) for High-Density Server Cooling pictures & photos
Coolant Distribution Unit (CDU) for High-Density Server Cooling
Coolant Distribution Unit (CDU) for High-Density Server Cooling pictures & photos
Coolant Distribution Unit (CDU) for High-Density Server Cooling
Coolant Distribution Unit (CDU) for High-Density Server Cooling pictures & photos
Coolant Distribution Unit (CDU) for High-Density Server Cooling
  • Coolant Distribution Unit (CDU) for High-Density Server Cooling
  • Coolant Distribution Unit (CDU) for High-Density Server Cooling
    Coolant Distribution Unit (CDU) for High-Density Server Cooling
  • Coolant Distribution Unit (CDU) for High-Density Server Cooling
    Coolant Distribution Unit (CDU) for High-Density Server Cooling
  • Coolant Distribution Unit (CDU) for High-Density Server Cooling
    Coolant Distribution Unit (CDU) for High-Density Server Cooling
  • Coolant Distribution Unit (CDU) for High-Density Server Cooling
    Coolant Distribution Unit (CDU) for High-Density Server Cooling
  • Coolant Distribution Unit (CDU) for High-Density Server Cooling
    Coolant Distribution Unit (CDU) for High-Density Server Cooling
  • Coolant Distribution Unit (CDU) for High-Density Server Cooling
    Coolant Distribution Unit (CDU) for High-Density Server Cooling

Find Similar Products

Product Description

Product Description
Coolant Distribution Unit (CDU)
 

Product descriptions from the supplier

 

Coolant Dustribution Unit

 

Product Description

 Description

The Coolant Distribution Unit (CDU) is the central component of the water cooling system, responsible for efficiently distributing the cooling medium to meet the cooling needs of various applications. It ensures the system operates stably by incorporating additional monitoring and support devices. The CDU on the secondary side of the heat exchange unit is primarily used for controlling heat exchange in liquid cooling heat sink systems. This system includes a frequency conversion circulating pump, plate heat exchanger, electric control valve, temperature sensor, pressure sensor, filter, expansion tank, flow meter, and online liquid replenishment function. It is pre-installed and tested at the factory to reduce on-site workloads.

 

Coolant Distribution Unit (CDU) for High-Density Server CoolingCoolant Distribution Unit (CDU) for High-Density Server Cooling

 

Performance range

· Heat transfer quantity:350~1500kW
Coolant Distribution Unit (CDU) for High-Density Server CoolingCoolant Distribution Unit (CDU) for High-Density Server Cooling

 

Model   CDU020W-080W 

Coolant Distribution Unit (CDU) for High-Density Server CoolingCoolant Distribution Unit (CDU) for High-Density Server Cooling
Features

· 10-inch touch screen, multi-level authority control;

· Modular design, can be increased according to the demand;

· (Optional) Double back-up high-efficiency frequency conversion pump automatically adjusts the flow rate according to the loaded condition;

· (Optional) Dual power supply backup;

· Corrosion-resistant 304 stainless steel and above material piping components;

· Standard Venttk liquid-cooled data center function control system, temperature monitoring, secondary side temperature control, flow and differential pressure control, anti-condensation protection, conductivity monitoring (optional), water turbidity monitoring (optional), water hardness monitoring (optional), PH value monitoring (optional);

· Ultra-quiet motor, low noise, long service life;

· Standard Modbus TCP communication protocol, rich detection, alarm and protection functions in the system, automatic protection of the setup parameters, power-down will not lose the operating parameters and alarm records;

· Provide standard communication protocol, can be customized according to customer demand for special format monitoring protocol;

· Secondary side filtration precision: 25~100 (μm) ultra-wide design range.

 

 

Our Advantages
    With Venttk's cutting-edge design, the CDU enhances the efficiency and dependability of the water cooling system. It boasts six channels that link the main pipeline to the secondary water separator of the water-cooled cabinet, eliminating installation and production errors with the use of clamps and rubber hoses.

    Venttk's CDU features a multi-stage centrifugal pump for circulating industrial water, ensuring a smooth and reliable flow of coolant. An expansion tank is integrated into the CDU to compensate for temperature fluctuations, maintaining consistent pressure levels and ensuring the system's reliable operation.

    To prevent issues like oxidation corrosion, inadequate circulation, and cavitation of the circulation pump, Venttk's CDU includes an automatic air vent valve on the top of the makeup water tank/main pipeline. This valve promptly eliminates non-condensable gases from the system.

    Furthermore, Venttk's CDU is equipped with a 150μm filter in its main path to preserve the quality of the coolant, guaranteeing the steady and secure operation of the entire system.

 

 
Coolant Distribution Unit (CDU) for High-Density Server Cooling
 
Coolant Distribution Unit (CDU) for High-Density Server CoolingCoolant Distribution Unit (CDU) for High-Density Server Cooling
 
 
 

 

 

 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2241984". Items marked "verified" are certified.

Watch Video
Watch Video
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.

About Our Factory & Business Background

Address
Room 1801, Building 1, Lane 1100, Lanzhou Road, Yangpu District, Shanghai, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, EXW, Others
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month
Nearest Port
SHANGHAI, GUANGZHOU, QINGDAO

Our Production Capability & Technical Expertise

Main Products
Air Conditioning, Refrigeration Unit, Chiller, Condenser Units, Plate Heat Exchanger, Dry Cooler, Air Cooler, Condenser, Evaporator, Shell and Tube Heat Exchanger

Our Industry Experience & Global Business Record

Export Year
2009-01-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the warranty period for the CDU?
The product comes with a 1-year warranty and online support services after the warranty period.
Can the liquid flow rate be customized?
Yes, the liquid flow rate is fully customized to meet specific cooling requirements.
What materials are used for the piping components?
The piping components are made of corrosion-resistant 304 stainless steel or higher grade materials.
Is the system pre-assembled before shipping?
Yes, the CDU is pre-installed and tested at the factory to reduce on-site installation workload.
What are the optional features available?
Optional features include double-backup high-efficiency frequency conversion pumps, dual power supply backup, and various monitoring options like conductivity and turbidity.
What is the filtration precision of the system?
The secondary side filtration precision has an ultra-wide design range of 25 to 100 microns.
Does the CDU support custom communication protocols?
Yes, it supports standard Modbus TCP and can be customized according to customer demand for special format monitoring protocols.
What is the typical lead time for production?
The lead time is one month during the off-season and 1-3 months during the peak season.