Clean Room Operating Room HEPA Filter Air Handling Unit

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Still deciding? Get samples of US$ 2000/Piece
Request Sample
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • Clean Room Operating Room HEPA Filter Air Handling Unit
  • Clean Room Operating Room HEPA Filter Air Handling Unit
  • Clean Room Operating Room HEPA Filter Air Handling Unit
  • Clean Room Operating Room HEPA Filter Air Handling Unit
  • Clean Room Operating Room HEPA Filter Air Handling Unit
  • Clean Room Operating Room HEPA Filter Air Handling Unit
Find Similar Products

Basic Info.

Model NO.
GT-ZKW80
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Mechanical Engineering
Mounting
Floor Standing
Lifetime
15~20 years
Certification
RoHS, ISO, CE
Condition
New
Transport Package
Wrap Film
Specification
Customized
Trademark
Venttech
Origin
Shanghai, China
HS Code
84159090
Production Capacity
2000PCS/Month

Product Description

Feature:
1, Complying with above China Standard, which is from ARI standard. ISO9001 and ISO14001 qualified.
2, Choose best materials, main components are from China top brand or imported.
3, The modular casing design, easy interchanging each other. easy install,easy transport,easy maintaince.
4, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%;
5, With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc.
6, High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg
7, Strong structure, good looking and permanent color.
8, Reasonable inside structure, with the suitable space for maintenance and cleaning.
9, Casing sheet: Provide double-skin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak.
The combined air handling untis are modular designed ,each modular can be used independently and can also work together and company with fan coil units to add refresh air. Not only reduce operation costs and energy saving, but also optimize air quality and create a congnitive indoor space to meet the human health requirements.

Technical Data

Clean Room Operating Room HEPA Filter Air Handling Unit


 
unit characteristics Model: GT-ZKW-()DX 20 30 40 50 65 80 100
Cooling capacity KW 10.1 15.3 20.3 25.5 32.3 38.6 52.0
Heating capacity KW 10.3 15.7 20.8 26.1 33.5 39.5 53.2
Supply air volume M³/h 2000 3000 4000 5000 6500 8000 10000
Margin blast pressure Pa 200 250 300 300 400 400 500
Power 3N-380V-50Hz
 
 
 
 
 
 
 
 
Indoor unit
Blower Type High efficient centrifugal fan
KW 0.55 0.75 1.5 2.2 3.0 3.0 5.5
Chilled water coil
(option)
Type High efficient copper tube aluminum fin
Water flow
(m³/h)
1.7 2.6 3.5 4.4 5.6 6.6 8.9
Segment length
(mm)
300 300 300 300 300 300 300
Heater Type Stainless steel tubular electric heater/ Steam heat coil/ Hot water heat coil
KW 6 9 12 18 24 24 30
segment length
(mm)
300 300 300 300 400 400 400
Humidifier Type Electrode type/ Steam/ Electrothermic type/ Wet film
KW 3 4 5 8 8 12 12
segment length
(mm)
400 400 400 400 400 400 400
Air filter Type Primary filter G4( Middle filter F8 &Nanocrystalline carbon filter)
Noise dB(A) 60 60 61 62 63 63 65
Size L (mm) 1800 2000 2000 2100 2100 2200 2400
W (mm) 730 1030 1030 1030 1140 1340 1340
H (mm) 788 788 1115 1115 1115 1115 1420
Weight KG 140 180 320 400 580 660 800
Outdoor unit Model: GT-WL- 10 15 20 25 35 40 55
Compressor A Type Hermetic Scroll ( Fixed frequency system)
Quantity 1 1 1 1 1 2 2
Input power A KW 3.4 4.8 6.3 8.0 9.8 12.7 16.1
Compressor B Type Hermetic Scroll( Frequency conversion system)
Quantity 1 1 1 1 1 2 2
Input power B KW 3.3 4.6 6.2 7.7 9.7 12.6 15.6
Refrigerant Type R22/R407C/R410A
Mode Thermal expansion valve/ Electronic expansion valve
Noise dB(A) 63 63 64 64 65 65 76
Size L (mm) 850 850 980 980 980 1880 1880
W (mm) 850 850 980 980 980 980 980
H (mm) 1080 1080 1080 1080 1234 1080 1080
Weight KG 130 135 150 180 220 280 320
Connection Pipe diameter liquid pipe(mm) 12.7
(9.52)
12.7
(9.52)
12.7
(12.7)
15.88
(12.7)
15.88
(12.7)
15.88*2
(12.7*2)
15.88*2
(12.7*2)
gas pipe(mm) 15.88
(12.7)
19.05
(15.88)
19.05
(15.88)
28.6
(22.23)
15.88
(12.7)
22.23*2
(19.05*2)
28.6*2
(22.23*2)


Application
The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.


Technology purification occasion/ operating room drawing

Clean Room Operating Room HEPA Filter Air Handling Unit
Clean Room Operating Room HEPA Filter Air Handling Unit
Clean Room Operating Room HEPA Filter Air Handling Unit


Clean Room Operating Room HEPA Filter Air Handling Unit

Contact name: Alina Shi
Tel: 0086 021 35324169-207
Mob: 0086 18321717548



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier