Air Cooling Radiator Generator Radiator

Product Details
Customization: Available
After-sales Service: Online Support
Warranty: 1 Year
Still deciding? Get samples of US$ 25000/Piece
Request Sample
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • Air Cooling Radiator Generator Radiator
  • Air Cooling Radiator Generator Radiator
  • Air Cooling Radiator Generator Radiator
  • Air Cooling Radiator Generator Radiator
  • Air Cooling Radiator Generator Radiator
  • Air Cooling Radiator Generator Radiator
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
D2-148-4*630
Cooling Water
Industrial Water
System Type
Open System
Fans Species
Double-speed fan
Noise Level
Low
Application Fields
Machinery
Certification
RoHS, ISO
Condition
New
Product Name
High Quality Intelligent Process Dry Cooler
Cooling Capacity
148kw
Water Flow
60L/Sec
Fan Quantity
14PCS
Power Supply
400V-3pH-50Hz
Total Motor Power
38.5kw
Inlet/Outlet Connection
DN125
Inlet Air Temperature
20 Degree C
Inlet/Outlet Water Temperature
35/25 Degree C
OEM Customization
Supported
Weight
Customized
Size
Customized
Air Discharge Direction
Vertical/Horizontal
Structure Type
V Type/Plate
Air Volume
Customized
Transport Package
Wrap Film/Pallet
Specification
refrigerant unit
Trademark
VENTTK
Origin
China
HS Code
8415901000
Production Capacity
100units/Month

Product Description

High quality intelligent process dry cooler
 
Dry Coolers are widely used in refrigeration, air-conditioning, food processing, heating plants and power plants.
Product Description

General productions:
  1. Suitable environment
  2. Dry Cooler series:D1 and D2 series.
  3. Environment temperature:  35ºC.
  4. Air does not contain chemical substances, corrosive gasses and dust-free;
  5. Please specify requirements for explosion-proof upon order
  6. Design Conditions:   Design pressure 2.0MPa; Test pressure 2.5MPa                
  7. Medium: WATER    
Working conditions:
Environment Specifications
Ambient Temperature 35ºC,                                  Inlet Temperature 48 ºC,Outlet Temperature 39 ºC     D4 Series
 
Details:
Sign Name Function
A Stand Fix equipment
B MetalSheet Casing Galvanized Steel Coated Casing
C Cooling Coil Al Fin and Copper Tube
D Fan Low Energy consumption fan to maximize air flow and low noise
 
Order No. PJO-2016SHSL08145 Product name Dry Cooler Model SHSL-D4-362-6X910F1 Order quantity 1 Gist: JB/T  7659.5-1995
Inspection item    Processing quality                                                                        Processing quality Air pressure test Insulation resistance Electric strength Whole set of products Nameplate and factory file Determine
Item number COIL Length
L≤1000(±2mm)
L>1000(±4mm)
COIL Diagonal
D≤1000(±3mm)
D>1000(±5mm)
Fin pattern Fin: conform to the requirements, no burr, no Rip, no pour, no dew copper, no wrinkles, no burning out.
 
Sheet metal: no scratches and deformation, surface should be clean, smooth, colours and luster is consistent, uniform coating.
 
With ≥1.15 times design pressure to test, no leakage and deformation. Design value: 2.5MPa
 
Electric parts to ground ,to the charged metal parts of the insulation resistance(cold)  2MΩ
 
1800V voltage,keep one minute, no puncture ,no flashover
 
Inlet and outlet connectors;flange ,fan,electric heating tube bracket,valves and so on.
 
content is complete,same with the good, factory file is complete, the specification is correct
2016D08145-001 3300/3303
3300/3304
 3672/3675
3675/3675
Aluminum fin 0.115mm
,2.2mm/ Ripple
Accord Accord 10min/2.5MPa
 
NO NO Accord Accord Qualified
   

Site assessment
Selected installation site must meet the following requirements:
  1. Level Ground;
  2. Ground or Floor strength able to support the wedight of equipment;
  3. no obstructions at air outlet.
  4. Upon confirming above conditions, take the following installation steps. Forklift or lifting product out of wooden pallets, loosen transport screw at stand and tighten after raising the screws to same horizontal plane as product. After moving product to the predetermined location, bolt tightly with large washer and spring washer.
 

Warning
  1. Minimize bias and ensure the level of the product during installation.
  2. Ensure tubes level and no loosen parts in dry cooler
  3. During installation, avoid weight of pipeline on the dry coolers.  
 
  1.  Wiring
  2. Power requirements:       
  3. Axial Fan power wiring: Axial fans are often using one phase or 3 phase motor. The 3 phase motor has two configuration, Y-shape and Shape
  4. Fan motor should have reliable power supply equipped with over voltage, under voltage and over current protection. Each fan is equipped with current protection settings. Internal thermal protection devise should be connected to the control lines to prevent damage to the motor due to over voltage, under voltage, lack of phase, contact failure. Motor wiring shall be installed according to the requirements when using two-speed motor.
 
warning
 
  1. Motor overcurrent protection and built in thermal protection settings must be connected.
  2. Electrical connections must be completed by qualified professionals
  3. Ensure wiring are correct and accurate to prevent motor failure
 
Electrical Installation
 
Warning
 
  1. Equipment installation must be done by qualified personnel
  2. Ensure all electrical circuits are installed in accordance GB 8877-88(household appliances installation, use, maintenance and safety requirements) or any other local regulations
  3. Equipment shall be safely grounded with resistance less than 2Ω
  4. Ensure all fan connecting cables are according to required standards of fan manufacturers.
 
Equipment commissioning
4.1  power on check
Check to ensure all requirements above are met. All requirements is to be met before trial run. Ensure all accessories are installed securely before powering on.
 
4.2  Power supply check
Ensure voltage and power supply matches name plate by measuring equipment and is safely grounded with less than 2ohm before power up.
 
4.3  Trial Operation
Ensure each fan is tighten and is not obstructed prior to commissioning. Rotation of the motor must be accordance with the factory specification. Ensure no jamming and free rotation to fan and motor. 

Photos show:
Air Cooling Radiator Generator Radiator
Air Cooling Radiator Generator Radiator
Air Cooling Radiator Generator Radiator
Air Cooling Radiator Generator Radiator
Air Cooling Radiator Generator Radiator
Air Cooling Radiator Generator Radiator



 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier