Model NO.
GT-WKR-90
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Mechanical Engineering
Mounting
Floor Standing
Lifetime
>20 years
Certification
RoHS, ISO
Condition
New
Product
Air Conditioner
Cooling Capacity
40kw
Heating Capacity
37.1kw
Supply Air
5800
Power
3n-380V-50Hz
Compressor
Efficient Scroll Closed
Evaporator
Tube Fin Heat Exchanger
Condenser
Tube Fin Heat Exchanger
Refrigerant
R22/R407c
Air Filter
Initially Effect Plate Filter
Transport Package
Export Packaging
Specification
850kg
Trademark
VENTTECH
Origin
Shanghai, China(Mainland)
HS Code
8415830000
Production Capacity
1500units Per Month

Product Description

packaged heat pump type rooftop air conditioner Description:
1. Air cooled rooftop air conditioner.
2. Cooling capacity: 8kw to 90kw, a variety of choices.
3. High external pressure.
4. Applicable to residential and commercial buildings, hotels, and scientific research units, factories and enterprises and so on.
   GT-WKR Series-Roof Top AH Specifiaction 1
Model   GT-WKR- 40 50 60 70 90 110 120
Specification Cooling capacity 1* kW 42 52.8 61.2 70.2 87.5 105.1 122.5
Heating capacity  2* kW 44.1 55.4 62.5 73.8 92.8 112 130
Supply air 3* m3/h 7000 8600 10000 12000 14500 17000 20000
Static pressure 3* Pa 300 300 300 350 350 400 400
Noise 4* dB(A) 68 69 69 70 71 72 72
Power 3N-380V-60Hz
Total capacity 17.24 20.72 23 29.76 39.1 44.66 51.58
Color White
ooling system Compressor Type Efficient scroll closed
Quantity 2 2 2 2 2 4 4
Supply air fan Type Low noise centrifugal type
Capacity kW 2.2 3 4 4 5.5 7.5 7.5
Evaporator Type Inner grooved copper tube and aluminum fin
Fin type 5* Slotted fin hydrophilic aluminum fin
Condenser Type Inner grooved copper tube and aluminum fin
Fin type 5* Rippled hydrophilic aluminum fin
Condenser fan Type Low noise axial type
Quantity 2 2 2 4 4 4 4
Refrigerant Refrigerant R22/R407C
Refrigerant control External balance type thermal expansion valve
Air filter Initially effect plate filter
Dimensions L mm 2200 2600 2600 3200 3200 6000 6000
W mm 1800 2200 2200 2200 2200 2300 2300
H mm 1520 1700 1700 1900 1900 2300 2300
Weight kg 850 1100 1250 1400 1650 1850 2200
1.     Cooling condition: Indoor dry bulb/wet bulb:29/19C,Outdoor dry bulb/wet bulb:46/24C
2.     Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6C;
3.     The air volume and static pressure`s specification in the table is standard, and can be designable.
4.     Noise data is measured in the front of the units when cooling under the standard air volume.
5.     Fin type and material can be designable.

packaged heat pump type rooftop air conditioner Features:
1. It is packaged air conditioner which integrates condensing part, evaporating part & control part into a whole unit, firstly promoted & applied in South America, North Europe & Australia.

2. It is air cooled direct evaporation & expansion air conditioner, has no need on cooling water & chilled water system, dispenses with cooling tower/cooling water pump/chilled water pump,  relative pipe work, electric control & terminal equipments, saves user investment.

3. It integrates evaporating part & condensing part into a whole unit which is installed outside to save indoor space, user will only need to install the duct, no need to connect refrigerant pipe work, it works under intellectual control without special care.
 
Application range:
It is mainly applied to factories, schools, auditoriums, warehouses, etc.

Structure:
1. Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
2. Direct expansion coils with condensate drain tray.

Hermetic compressor
1. High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
2. Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.

Centrifugal fan
1. Forward curve centrifugal fans for air treatment section and axial fans for condensation section.
2. Front, side and underside air discharge of the treatment unit.
3. High external pressure, long air supply distance.

Electric panel
1. Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components
2. Easy operation line controller
3. Cooling/Heating/Auto
3. Error indication
4. Timing on/off

Optional
1. Economizer with fresh, return air dampers and fresh air hood
2. Free cooling function for low ambient temperature
3. Low ambient control device for operation of outdoor units at ambient temperatures from less than 20C down to -10C
4. BMS devices
4. T3 (Tropical climate)
5. Condenser coil guard
6. Roof curb
7. Metal / aluminum filter
8. Air pressure switch for indoor fan
9. High static condenser fan option with sealed + drain condensing section
10. Optional water heating coil
11. Metal or plastic mesh on condenser coil
12. Optional supply / return air configurations
13. Upgraded evaporator fan motor drives
14. G4 filter, plate and bag filter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier