Portable AC Package Unit for Event Exhibition Tent

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • Portable AC Package Unit for Event Exhibition Tent
  • Portable AC Package Unit for Event Exhibition Tent
  • Portable AC Package Unit for Event Exhibition Tent
  • Portable AC Package Unit for Event Exhibition Tent
  • Portable AC Package Unit for Event Exhibition Tent
  • Portable AC Package Unit for Event Exhibition Tent
Find Similar Products

Basic Info.

Model NO.
  GT-WKR-120
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Ultra Low
Application Fields
Hospital, Factory
Mounting
Floor Standing
Lifetime
15~20 years
Certification
RoHS, UR
Condition
New
Product
Rooftop Air Conditioner
Air Volume
3500 M3/H
Cooling Capcity
10.5kw
Rerigeration
R22/R407c/R134A
Compressor
Copland
Transport Package
Customerized Packing
Specification
UL
Trademark
Venttk
Origin
Shanghai, Ningbo
HS Code
8415830000
Production Capacity
350 Units/Month

Product Description

Rooftop air conditioner Package unit
Portable AC Package Unit for Event Exhibition Tent



Portable AC Package Unit for Event Exhibition Tent
Features
Description:
1. Air cooled rooftop air conditioner.
2. Cooling capacity: 8kw to 90kw, a variety of choices.
3. High external pressure.
4. Applicable to residential and commercial buildings, hotels, and scientific research units, factories and enterprises and so on.

Feature:
1. Evaporator: Type Inner grooved copper tube and aluminum fin
2. Fin Type 5* :Slotted fin hydrophilic aluminum fin
3. Condenser: Type Inner grooved copper tube and aluminum fin
4. Fin Type 5* :Rippled hydrophilic aluminum fin
5. Condenser Fan Type: Low noise axial type
 
Technical Data
   GT-WKR Series-Roof Top AH Specifiaction 1  
Model   GT-WKR- 10 15 18 20 25 30 35  
 
Specification Cooling capacity 1* kW 10.5 15.0 18.5 21.0 26.3 29.8 35.0  
Heating capacity 2* kW 11.5 15.9 19.5 22.1 27.6 32.6 37.1  
Supply air 3* m3/h 1800 2400 2900 3500 4500 5000 5800  
Static pressure 3* Pa 100 150 150 180 200 250 250  
Noise 4* dB(A) 60 60 62 62 65 65 68  
Power 3N-380V-60Hz  
Total capacity 3.9 5.74 7.0 8.27 9.96 11.0 14.15  
Color White  
ooling system Compressor Type Efficient scroll closed  
Quantity 1 1 1 1 1 1 2  
Supply air fan Type Low noise centrifugal type  
Capacity kW 0.37 0.55 0.75 0.75 1.1 1.5 2.2  
Evaporator Type Inner grooved copper tube and aluminum fin  
Fin type 5* Slotted fin hydrophilic aluminum fin  
Condenser Type Inner grooved copper tube and aluminum fin  
Fin type 5* Rippled hydrophilic aluminum fin  
Condenser fan Type Low noise axial type  
Quantity 1 1 1 1 1 1 2  
Refrigerant Refrigerant R22/R407C  
Refrigerant control External balance type thermal expansion valve  
Air filter Initially effect plate filter  
Dimensions L mm 1400 1400 1600 1600 1850 1850 2200  
W mm 1050 1050 1200 1200 1400 1400 1800  
H mm 1050 1050 1050 1050 1200 1200 1520  
Weight kg 200 230 260 300 550 600 850  
1.  Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
2.  Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6ºC;
3.  The air volume and static pressure`s specification in the table is standard, and can be designable.
4. Noise data is measured in the front of the units when cooling under the standard air volume.
5. Fin type and material can be designable.
   GT-WKR Series-Roof Top AH Specifiaction 1  
Model   GT-WKR- 40 50 60 70 90 110 120  
 
Specification Cooling capacity 1* kW 42.0 52.8 61.2 70.2 87.5 105.1 122.5  
Heating capacity  2* kW 44.1 55.4 62.5 73.8 92.8 112.0 130.0  
Supply air 3* m3/h 7000 8600 10000 12000 14500 17000 20000  
Static pressure 3* Pa 300 300 300 350 350 400 400  
Noise 4* dB(A) 68 69 69 70 71 72 72  
Power 3N-380V-60Hz  
Total capacity 17.24 20.72 23.0 29.76 39.1 44.66 51.58  
Color White  
ooling system Compressor Type Efficient scroll closed  
Quantity 2 2 2 2 2 4 4  
Supply air fan Type Low noise centrifugal type  
Capacity kW 2.2 3 4 4 5.5 7.5 7.5  
Evaporator Type Inner grooved copper tube and aluminum fin  
Fin type 5* Slotted fin hydrophilic aluminum fin  
Condenser Type Inner grooved copper tube and aluminum fin  
Fin type 5* Rippled hydrophilic aluminum fin  
Condenser fan Type Low noise axial type  
Quantity 2 2 2 4 4 4 4  
Refrigerant Refrigerant R22/R407C  
Refrigerant control External balance type thermal expansion valve  
Air filter Initially effect plate filter  
Dimensions L mm 2200 2600 2600 3200 3200 6000 6000  
W mm 1800 2200 2200 2200 2200 2300 2300  
H mm 1520 1700 1700 1900 1900 2300 2300  
Weight kg 850 1100 1250 1400 1650 1850 2200  

Note:
1. Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
2. Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6ºC;
3. The air volume and static pressure`s specification in the table is standard, and can be designable.
4. Noise data is measured in the front of the units when cooling under the standard air volume.
5. Fin type and material can be designable.

Portable AC Package Unit for Event Exhibition TentPortable AC Package Unit for Event Exhibition Tent

For Further information could contact
Alicia
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.