50 Ton Commercial Rooftop AC Air Conditioner Heat Pump

Product Details
Customization: Available
After-sales Service: Online Support
Warranty: 1 Year
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • 50 Ton Commercial Rooftop AC Air Conditioner Heat Pump
  • 50 Ton Commercial Rooftop AC Air Conditioner Heat Pump
  • 50 Ton Commercial Rooftop AC Air Conditioner Heat Pump
  • 50 Ton Commercial Rooftop AC Air Conditioner Heat Pump
  • 50 Ton Commercial Rooftop AC Air Conditioner Heat Pump
  • 50 Ton Commercial Rooftop AC Air Conditioner Heat Pump
Find Similar Products

Basic Info.

Model NO.
D2-012-3X350
Air Tube Material
Galvanized Sheet
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Mechanical Engineering
Mounting
Floor Standing
Lifetime
15~20 years
Certification
ISO, CE
Condition
New
Input Power
3n-380V
Frequency
60Hz/50Hz
Color
White(According to Customer Requirements)
Compressor
Efficient Scroll Closed
Refrigerant
R22/R407c
Function
Cooling/Heating
Airflow
1800-80000
Cooling Capacity
Adjustable
Constant Temperature and Humidity
Optional
Name
Air Conditioner Rooftop Unit
Transport Package
Packaged Air Conditioner
Specification
RoHS, CE
Trademark
Shenglin
Origin
Shanghai, China
HS Code
8415822090
Production Capacity
1000unit Per Month

Product Description

Rooftop Air Conditioning Unit

1) BRIEF INTRODUCTION AND FEATURES
Rooftop air-conditioning unit is DX air-cooled type, combined of the refrigeration system, control systems and different air handling sections, achieving cooling, heating, dehumidification, humidification, air purification, sterilization and other functions.Complete with a wide cooling capacity range, no need cooling water system, omit the dedicated room and complex cooling towers, water pumps and the corresponding pipelines, control device. Unit usually mounted on the roof or other outdoor location, don't need dedicated room, which greatly save the cost of civil work. Besides, It's easy to install--- only to connect the duct then power on to run, which also save the cost of maintenance.
50 Ton Commercial Rooftop AC Air Conditioner Heat Pump

2) Main Unit Descriptions
1) Efficient and Energy-saving.
Each outdoor unit incorporates high efficiency scroll compressors.
Coils use high efficient inner screw copper tube for better heat transfer.
Fresh air non energy dissipating cooling in transient season, can adjust air volume what the fresh air system
required.
OEM energy recovery device.
2) Durable( corrosion and rust protection).
Our packaged systems are built tough towithstand all weathers.
Their durable construction ensures a long life and excellent return on your investment.
The outdoor air coils' aluminum fins could be epoxy coated for extra protection in corrosive environments, e.g. salt
laden sea air.
Blue-fin type coils, epoxy resin fin coils as well as the copper fin coils are also available as an option.
Cabinets are constructed from high grade steel - polyester powder coated for all weather protection.
External fasteners are stainless steel or galvanized type.
Corrosion resistant drain trays are also included.
Designed to evacuate rain water and condensed water easily from the unit.
The opening for the connection side ducts are protected
so that water will not splash on the joint between the duct and unit panel.

3)Safety.
Complete with various protecting function.
Pass kinds of safety tests.
4) Easy service.
Quick release fasteners are provided on electrical and compressor panel.
The units are equipments with access door to all components that may require maintenance or service.
The liquid sight glasses are visible and easy to find.
Access to the control circuit and compressor section is independent of the cooling or heating operation of the unit.
5) Options.
Electric heater, hot-water heating, steam-heating unit.
Manul/electric fresh air damper, plug fan, dedicated exhaust fan air filter dirty alarm device.
Energy recovery device.


50 Ton Commercial Rooftop AC Air Conditioner Heat Pump

Standard heat pump type rooftop air conditioner
Spec table 1
Model WRF12ZA WRF 15ZA WRF18ZA WRF24ZA WRF30ZA WRF 35ZA
WF12ZA WF 15ZA WF18ZA WF24ZA WF30ZA WF 35ZA
Cooling capacity kW 12 15.2 17.5 24 30.3 35.6
Heating capacity kW 13.2 16.6 18.4 26.5 33.3 37.7
Energy regulation
 
% 0,100% 0,50,100%
Power 380V / 3Ph / 50HZA
Cooling input capacity kW 4.1 5.3 5.5 8.8 11.3 12.3
Heating input capacity kW 3.8 4.8 5.1 8.2 10.4 11.3
Start current A 48 62 63 63 74 76
Cooling running current A 7.4 9.7 10.2 16.1 21.2 23.3
Heating running current A 6.9 9.2 9.7 15.1 20.1 22.2
Throttling method
 
Thermal expansion valve
 
Cooling system 1 1 1 1 2 2
Refrigerant R410A
Compressor Compressor type Hermetic scroll compressor
 
Qty 1 1 1 1 2 2
Condensation side
 
 
Condenser Type Copper tube and aluminum fin
Qty 1 1 1 1 1 1
Drive type Direct drive
Motor power kW 0.25 0.37 0.37 0.55 0.75 0.75
Air volume m3 /h  4600 7800 7800 9000 12600 12600
Evaporation side
 
 
Evapotator Type Copper tube and aluminum fin
Qty 1 1 1 1 1 1
Motor power kW 0.32 0.37 0.45 1.1 1.5 2.2
Air volume m3 /h 2100 2600 3400 4100 5200 6300
Drive type Direct drive Pulley
Static pressure(Pa) 100 100 100 200 200 250
Filter Aluminum filter G3
Noise dB(A) 67 67 68 71 72 72
Refrigerant filling volume(kg) 3.1 3.1 4.3 2x3.1 2x3.1 2x4.3
External dimension L mm 1410 1410 1410 1978 1978 1978
W mm 1100 1100 1100 1175 1175 1175
H mm 1095 1095 1095 1095 1095 1095
Weight kg 240 260 290 420 480 500

Note: 1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27ºC/19ºC and outdoor DB/WB temperature is 35ºC/24ºC condition;
2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20ºC/15ºC and outdoor DB/WB temperature is 7ºC/6ºC condition;


Spec table 2
Model WRF45ZA WRF50ZA WRF 60ZA WRF72ZA WRF 90ZA WRF105ZA
WF 45ZA WF 50ZA WF 60ZA WF 72ZA WF90ZA WF 105ZA
Cooling capacity kW 44.5 50 60 70 90 105
Heating capacity kW 48.7 54.3 64 75.4 96.2 113.2
Energy regulation
 
% 0,33,66,100 0,30,70,100 0,50,100 0,50,100 0,33,66,100 0,33,66,100
Power   380V / 3Ph / 50HZA
Cooling input capacity kW 17 19.5 22.8 26.7 32.9 39.7
Heating input capacity kW 15.6 18 21 24.8 30.4 36.7
Start current A 168 186 175 199 197 266
Cooling running current A 31.7 35.6 39.9 48.3 61 70.6
Heating running current A 29.9 33.5 37.5 45.4 57.3 66.3
Throttling method
 
                                   Thermal expansion valve
 
Cooling system 1  
Refrigerant R410A
Compressor Compressor type Hermetic scroll compressor
   
Qty 2 2 2 2 3 3
Condensation side
 
Condenser Type Copper pipe copper fin
Fan Qty 1 1 1 1 2 2
Drive type Direct drive
Motor power kW 1.1 1.5 1.5 2.2 2X1.1 2X1.5
Air volume m3 /h 16500 21000 21000 27000 33000 42000
      a 2.65 3.82 3.82 5.49 2.65 3.82
      kw 1.14 2.02 2.02 2.875 1.14 2.02
Evaporation side
 
Evaporator Type Evaporator
  Qty   1 1 1 1 1
Motor power   3 3 4 4 5.5 5.5
Air volume   7600 8500 10900 12500 16000 19500
Drive type  
Static pressure(Pa) 250 250 300 300 300 300
Filter Aluminum filter G3
Noise dB(A) 73 73 73 75 74 75
Refrigerant filling volume(kg) 4.3+ 4.3+8.5 2x7.5 2x8.5 3x7.5 3x8.5
External dimension L mm 2268 2268 2298 2298 2878 2878
W mm 1440 1440 1650 1650 2140 2140
H mm 1167 1167 1400 1400 1964 1964
Weight   750 770 880 960 1160 1350
Note: 1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27ºC/19ºC and outdoor DB/WB temperature is 35ºC/24ºC condition;
2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20ºC/15ºC and outdoor DB/WB temperature is 7ºC/6ºC condition;

Spec table 3
Model WRF120ZA WRF140ZA WRF150ZA WRF180ZA WRF210ZA WRF300ZA
WF120ZA WF140ZA WF150ZA WF180ZA WF210ZA WF300ZA
Cooling capacity kW 120 140 149 180 210 298
Heating capacity kW 128.3 150 159.2 192.5 226 318
Energy regulation
 
% 0,25,50,75,100 0,50,100 0,16.6,33.3,50,66.4,83,100 0,25,50,75,100
Power   380V / 3Ph / 50HZA
Cooling input capacity kW 45.1 55.7 55.1 69.9 83 106.7
Heating input capacity kW 41.7 51.8 51.5 64.8 77 100
Start current A 218 252 323 232 301 415
Cooling running current A 82.4 101.4 100.2 130.9 151 192.3
Heating running current A 77.4 95.7 95.1 123.5 142.3 184.3
Throttling method
 
        Thermal expansion valve
Cooling system 4 4 2 6 6 4
Refrigerant R410A
Compressor Compressor type Hermetic scroll compressor
380V / 3Ph / 50HZA
Qty 4 4 2 6 6 4
Condensation side
 
Condenser Type Copper pipe copper fin
Fan Qty 2 2 2 4 4 4
Drive type Direct drive
Motor power kW 2X1.5 2x2.2 2x2.2 4X1.1 4X1.5 4x2.2
Air volume m3 /h 42000 54000 54000 66000 84000 108000
Evaporation side
 
 
Evaporator Type Copper pipe copper fin
  Qty 1 1 1 1 1 1
Motor power kW 7.5 11 11 15 15 18.5
Air volume m3 /h 21000 25000 26000 32000 38000 54000
Drive type Pulley
Static pressure(Pa) 400 400   500 500 500
Filter Aluminum filter  G3
Noise dB(A) 75 79 79 80 80 82
Refrigerant filling volume(kg) 4x7.5 4x8.5 2x17 6x7.5 6x8.5    4x14
External dimension L mm 3626 3626 3626 4690 4690 5660
W mm 2200 2200 2200 2330 2330 2330
H mm 2047 2047 2047 2055 2427 2055
Weight kg 1710 1820 1850 2180 2430 2860
Note: 1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27ºC/19ºC and outdoor DB/WB temperature is 35ºC/24ºC condition;
2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20ºC/15ºC and outdoor DB/WB temperature is 7ºC/6ºC condition;








 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier