Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center

Product Details
Customization: Available
Warranty: 1 Year
Type: Air-Cooled
Still deciding? Get samples of US$ 2000/Piece
Request Sample
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
  • Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
  • Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
  • Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
  • Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
  • Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
Find Similar Products

Basic Info.

Cooling Water
Industrial Water
System Type
Open System
Fans Species
Double-speed fan
Noise Level
Low
Application Fields
Medical Equipment
Certification
RoHS, ISO, CE
Condition
New
Tube Material
Copper, Stainless Steel
Tube Diameter
5mm/7mm/7.94mm/9.52mm/12.75mm/15.88mm
Fin Material
Aluminum, Copper, Stainless Steel
Fan
Axial Fan
Fluid
Water, Glycol, Oil, Steam
Cooling Capacity
10-1000kw
Application
Solar Systems, Plastic Industry, HVAC
Transport Package
Wrap Film
Specification
Customized
Trademark
Venttech
Origin
Shanghai, China
HS Code
8419500090
Production Capacity
20000PCS/Month

Product Description

Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
Products Features

1. Condensers are the first choice of refrigeraion and AC industry. Condenser with a capacity 8kW~1800kW and surface 20~4100 square meter which has wide application range. It is flexible to match which different size of compressor. Use low specific energy consumption fans, high efficiency inner groove copper tube and sine wave aluminum fin. Durable material with slim but rigid enclosure hard gloss powder coated sheet metal offers corrosion proof under hostile environment. There are top air outlet or side air outlet construct for C1 series, "V" type for C2 series. C2 float coil can prevent refrigerant leakage effictively, it ensures a durable and safety finned heat exchanger.

2. High efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

3. Fan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan.

4. We facilitate you to have a long lasting and low maintainance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar.

Air discharge direction

Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center

Performance ranges

Cooling capacity: from 5 to 649 kw
Air volume: from 2828 to 263503 m3/h
Sound pressure level: from 31 to 69 dB A(10m)
Dry coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.
Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).
Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.
Fan nozzle designs for maximum air flow and air throw.
Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.
Motor: protection class IP 54 and insulation class F.
Voltage:400V/3N/50Hz
Air separator for each fan.

Testing

Heat exchangers are supplied clean and tested at a pressure of 30 bars

Options

Coil design refrigerant: water, oil, glycol.
Multiple circuits.
Sub-cooling circuits.
Stainless steel or aluminum casing.
Coated aluminum or copper fins.
Explosion ploof motor.
Customized fin spacing.
Hydropad.


 Technical parameter
Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center

Dry cooler D2 series parameter(fin space 2.1mm)
Type D2-148-4x630 D2-166-4x630 D2-175-4x630 D2-228-6x630 D2-250-6x630 D2-276-6x630 D2-310-8x630 D2-343-8x630 D2-364-8x630 D2-392-10x630
Capacity Water KW 147.99 165.85 175.21 227.85 250.42 276.53 309.85 342.73 364.07 391.99
20% Et. Glycol KW 142.42 161.57 170.91 219.09 244.69 270.22 301.18 333.55 354.64 383.3
Air flow M3/h 76459 74341 72134 114686 111511 108188 152911 148675 144255 191136
Fan No. X φ 2x2x630 2x2x630 2x2x630 2x3x630 2x3x630 2x3x630 2x4x630 2x4x630 2x4x630 2x5x630
Fan motor
400/3N/50HZ
A 20.4 20.4 20.4 30.6 30.6 30.6 40.8 40.8 40.8 51.00
Sound pressure level dB(A)10m 64 64 64 66 66 66 67 67 67 68
Dimension L mm 2186 2186 2186 3250 3250 3250 4250 4250 4250 5250
H mm 1874 1874 1874 1874 1874 1874 1874 1874 1874 1874
D mm 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100
D1 mm 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
L1 mm 963 963 963 963 963 963 963 963 963 963
L2 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
L3 mm 1963 1963 1963 2963 2963 2963 3963 3963 3963 4963
Connections inlet φ mm 2XDN50 2XDN65 2XDN65 2XDN65 2XDN80 2XDN80 2XDN80 2XDN80 2XDN100 2XDN100
Connections onlet φ mm 2XDN50 2XDN65 2XDN65 2XDN65 2XDN80 2XDN80 2XDN80 2XDN80 2XDN100 2XDN100
Product weight(empty) kg 769 811 853 1134 1197 1261 1498 1589 1673 1864
 
Type D2-426-10x630 D2-445-12x630 D2-517-12x630 D2-525-14x630 D2-601-14x630 D2-596-16x630 D2-692-16x630 D2-676-18x630 D2-783-18x630 D2-921-20x630
Capacity Water KW 426.15 444.78 516.67 524.70 601.41 595.59 692.11 676.02 783.03 921.23
20% Et. Glycol KW 413.85 427.83 504.38 507.90 586.16 572.94 676.71 653.42 767.64 905.78
Air flow M3/h 182123 229377 218543 267604 254816 301325 290850 338987 327612 351663
Fan No. X φ 2X5X630 2X6X630 2X6X630 2X7X630 2X7X630 2X8X630 2X8X630 2X9X630 2X9X630 2X10X630
Fan motor
400/3N/50HZ
A 51.00 61.20 61.20 71.40 71.40 81.60 81.60 91.80 91.80 102.00
kW 27.50 33.00 33.00 38.50 38.50 44.00 44.00 49.50 49.50 55.00
Sound pressure level dB(A)10m 68 69 69 70 70 71 71 72 72 73
Dimension L mm 5250 6250 6250 7250 7250 8250 8250 9250 9250 10250
H mm 1874 1874 1874 1874 1874 1874 1874 1874 1874 1874
D mm 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100
D1 mm 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000
L1 mm 963 963 963 963 963 963 963 963 963 963
L2 mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
L3 mm 4963 5963 5963 6963 6963 7963 7963 8963 8963 9963
Connections inlet φ mm 2XDN100 2XDN100 2XDN100 2XDN100 2XDN125 2XDN125 2XDN125 2XDN125 2XDN125 4XDN1100
Connections onlet φ mm 2XDN100 2XDN100 2XDN100 2XDN100 2XDN125 2XDN125 2XDN125 2XDN125 2XDN125 4XDN1100
Product weight(empty) kg 2193 2224 2617 2586 3259 3244 3728 3643 4226 4283
 
Application
Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.

Product schematic diagram
Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin CenterBc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center

 
Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center

Sucessful case
Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center
Bc888 Bitcoin Mining Cooling System Dry Cooler Use for Bitcoin Center

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier