Customization: | Available |
---|---|
Type: | Air-Cooled |
Cooling Water: | Water |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Shanghai Venttech refrigeration equipment Co., Ltd. is a professional dry air cooler for bitcoin immersion cooling system, condenser, evaporator manufacturer in China, which has more 17 years experience in HVAC area.
Dry type air cooler can be used in various cold storages such as architectural or constructional ones. Please refer to the following for general informations. For more details, please contact our sales staff.
By optimizing the refrigerant flow, finned tube material, frosting, wind speed, pipe arrangement, fin spacing and so on. To provide customers the dry cooler with high efficient, compact, light weight, high reliability, energy saving and environmental protection.
The copper tube and aluminum fin of the heat exchanger through the expansion tube process to reduce the contact resistance, increase the pressure of the contact between the aluminum fin and copper tube, so that bulge occur some deformation at the interface, then to reduce the gap, increase the contact area, reduce the contact resistance , enhance heat transfer. Because of the water or medium through the dry cooler, it must be light pipe, which can reduce the resistance of the liquid in the pipeline.
Through thermodynamic calculation, select the number of copper tube suitable for working conditions. In full consideration of gravity and resistance, strictly control the flow rate, reasonable layout, which can make the heat exchanger achieve the best heat exchange performance in the harsh conditions.
The heat exchanger select outer rotor-type fan with low energy consumption, fan motor protection class IP54, insulation class F, each motor with thermal protection, stable operation, long service life.
type | D1-028 | D1--034 | D1-041 | D1-058 |
cooling capacity kw | 28.09 | 33.62 | 41.21 | 58.15 |
water flow m3/h | 5 | 6 | 7.2 | 10 |
air flow m3/h | 19029 | 18289 | 16864 | 38056 |
Dry cooler Auxiliary System:
1. The spray system:
The spray system uses intermittent atomized water to spray on the intake flow to provide an adiabatic cooling effect, reducing the air temperature to near the wet bulb temperature, thereby helping to save a lot of energy and increase work. Improving heat exchange efficiency can increase heat dissipation under the same heat exchange area.
Adding a spray system to the induction cooling system can take away the heat of the circulating water in the data center for most of the year. The spray system increases the heat transfer capacity of the dry cooler, further reducing the operation of mechanical refrigeration.
2. Wet curtain(cooling pad) system:
This type of adiabatic pre-cooling allows return and condensation temperatures below the ambient temperature or a considerably higher unit performance with the same space requirements and improved system efficiency.
Performance range:
Capacity from 5 to 1920kW
(water, Tw1=40°C, Tw2=35°C, T1=25°C)
Fans:
Diameter Ø350, 450, 500, 630, 800, 910, 1250, 1800mm
AC or EC motor
Benefits:
Maximum performance, minimum footprint
High efficiency geometry
Modular design, 1~8 fans
Piping in copper or stainless steel AISI 304 or AISI 316L
Wide range of fin materials available
Options:
Coil design refrigerant: water, oil, glycol, BC888, Shell S3X and S5X
Multiple circuits
Sub-cooling circuits
Stainless steel or aluminum casing
Epoxy resin aluminum or copper fins
Explosion proof motor
Customized fin spacing
1.Capacity design according to the most popular compressor sizes in the range.
2.Fin and tube design for minimizing the latent heat and frost losses in balance with a lost efficient heat transfer coefficiency.
3.Chooses only low specific energy consumption fans, Stable in operation and long lasting ,fan nozzle design for maximum air flow and air throw.
4.Reasonable copper tube layout and arrangement, always consider the velocity and pressure drop so that we can get the best point for heat exchange.
5. Proved floating coil design,Good protection against leakage,Self-supporting casing structure. Minimal flexion during crane and forklift transport. Reduced assembly torsion.
6.Different running condition, welding process different.