High-Performance Water Cooling System for Data Center Cdu

Shanghai Venttech Refrigeration Equipment Co., Ltd.
  • Audited Supplier
  • 10 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • High Heat Transfer Capacity: Range from 350 to 1500kW for efficient data center cooling.
  • Modular Design: Allows flexible expansion according to specific demand.
  • Intelligent Control System: Features temperature, flow, and pressure control with anti-condensation protection.
  • Corrosion-Resistant Materials: Constructed with 304 stainless steel and above for long service life.
  • Ultra-Quiet Operation: Low noise motor suitable for quiet environments.
  • Customizable Monitoring Protocol: Special format monitoring protocols can be customized per customer requirements.
  • Dual Power Supply Backup: Optional dual backup pumps enhance system reliability.
  • Factory Pre-Installation: Pre-installed and debugged at factory to reduce on-site work.

Product Images of High-Performance Water Cooling System for Data Center Cdu

High-Performance Water Cooling System for Data Center Cdu
High-Performance Water Cooling System for Data Center Cdu pictures & photos
High-Performance Water Cooling System for Data Center Cdu
High-Performance Water Cooling System for Data Center Cdu pictures & photos
High-Performance Water Cooling System for Data Center Cdu
High-Performance Water Cooling System for Data Center Cdu pictures & photos
High-Performance Water Cooling System for Data Center Cdu
High-Performance Water Cooling System for Data Center Cdu pictures & photos
High-Performance Water Cooling System for Data Center Cdu
  • High-Performance Water Cooling System for Data Center Cdu
  • High-Performance Water Cooling System for Data Center Cdu
    High-Performance Water Cooling System for Data Center Cdu
  • High-Performance Water Cooling System for Data Center Cdu
    High-Performance Water Cooling System for Data Center Cdu
  • High-Performance Water Cooling System for Data Center Cdu
    High-Performance Water Cooling System for Data Center Cdu
  • High-Performance Water Cooling System for Data Center Cdu
    High-Performance Water Cooling System for Data Center Cdu

Find Similar Products

Product Description

High-Performance Water Cooling System for Data Center Cdu
Product Description

Introduction
    The Coolant Distribution Unit (CDU) is the core component of the water cooling system, responsible for efficiently distributing the coolant to meet various cooling needs. By integrating auxiliary monitoring and support devices, the CDU ensures stable operation of the system.
    It is mainly used for heat exchange control in liquid cooling systems, incorporating secondary side variable frequency circulating pumps, plate heat exchangers, electric control valves, temperature sensors, pressure sensors, filters, expansion tanks, flow meters, and online replenishment functions. The CDU is pre-installed and debugged at the factory, reducing on-site installation and commissioning work.


Performance Range

· Heat Transfer Capacity:350~1500kW


Features
· 10-inch Touch Screen: Multi-level authority control, easy to operate.
· Modular Design: Flexible expansion according to demand.
· High-Efficiency Variable Frequency Pump (Optional): Dual backup pumps automatically adjust flow rate, ensuring efficient operation.
· Dual Power Supply Backup (Optional): Enhances system reliability.
· Corrosion-Resistant Materials: Made with 304 stainless steel and above, ensuring long service life.
· Intelligent Control System: Includes temperature monitoring, secondary side temperature control, flow and differential pressure control, anti-condensation protection, and optional monitoring for conductivity, water turbidity, water hardness, and pH value.
· Ultra-Quiet Motor: Low noise and long service life, suitable for quiet environments.
· Standard Communication Protocol: Supports Modbus TCP, with comprehensive detection, alarm, and protection functions. Setup parameters are automatically protected, and operational parameters and alarm records are retained after power failure.
· Customizable Monitoring Protocol: Special format monitoring protocols can be customized according to customer requirements.
· Secondary Side Filtration Precision: Ultra-wide design range of 25~100μm, meeting various application needs.

Our Advantages
    With Venttk's innovative design, the CDU optimizes the performance and reliability of the water cooling system. It features six channels that connect the main circuit to the secondary water distributor of the water-cooled cabinet, reducing installation and production errors with the use of chucks and rubber hoses.
    Venttk's CDU incorporates a multi-stage centrifugal pump for industrial water circulation, ensuring efficient and reliable coolant flow. An integrated expansion tank compensates for temperature fluctuations, maintaining stable pressure levels and ensuring reliable system operation.
    To prevent issues such as oxidation corrosion, poor circulation, and cavitation of the circulation pump, the CDU includes an automatic air vent valve on the top of the makeup water tank/main pipeline, which promptly eliminates non-condensable gases from the system. 
    Additionally, the CDU is equipped with a 150μm filter in the main path to protect the quality of the coolant, ensuring the reliable and stable operation of the entire system.
    Choose Venttk's Coolant Distribution Unit (CDU) for a more efficient and reliable water cooling system.
High-Performance Water Cooling System for Data Center Cdu
 
Product Parameters
Model SLCDU020W SLCDU030W SLCDU040W SLCDU050W SLCDU060W SLCDU070W SLCDU080W
supply power 220V 1Ph 50Hz
Unit performance parameters
Primary side temp.

35/42 ºC,

Secondary side temp.
40/47
ºC
cooling capacity-kW 21.1  32.2  41.3  53.2  62.5  70.6  82.1 
Secondary side flow rate-m3/h 2.58  3.94  5.06  6.51  7.65  8.64  10.05 
Secondary side pressure drop-kPa 30.7  44.1  62.9  41.4  50.9  62.0  74.7 
Primary side flow rate-m3/h 2.58  3.94  5.06  6.51  7.65  8.64  10.05 
Primary side pressure drop-
kPa
41.2  55.3  74.9  54.5  65.3  78.0  92.5 
Rated power-kW 0.46  0.59  0.73  0.83  0.91  1.00  1.13 
FLA-A 4.26  4.26  4.26  5.97  5.97  5.97  8.81 
Primary side medium Softened water,ethylene glycol solution
Secondary side medium Deionized water,ethylene glycol solution,propylene glycol solution
Primary side pipeline DN32 DN32 DN32 DN40 DN40 DN40 DN40
Secondary side pipeline DN32 DN32 DN32 DN40 DN40 DN40 DN40
Interface type
Chuck

interface

Chuck

interface

Chuck

interface

Chuck

interface

Chuck

interface

Chuck

interface

Chuck

interface
Width    -mm 600  600  600  600  600  600  600 
Deep-mm 1200  1200  1200  1200  1200  1200  1200 
Height-mm 2000  2000  2000  2000  2000  2000  2000 
Weight-kg 200  200  200  220  220  220  220 

Factory

High-Performance Water Cooling System for Data Center Cdu
High-Performance Water Cooling System for Data Center Cdu
 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2241984". Items marked "verified" are certified.

Watch Video
Watch Video
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.

About Our Factory & Business Background

Address
Room 1801, Building 1, Lane 1100, Lanzhou Road, Yangpu District, Shanghai, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, EXW, Others
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month
Nearest Port
SHANGHAI, GUANGZHOU, QINGDAO

Our Production Capability & Technical Expertise

Main Products
Air Conditioning, Refrigeration Unit, Chiller, Condenser Units, Plate Heat Exchanger, Dry Cooler, Air Cooler, Condenser, Evaporator, Shell and Tube Heat Exchanger

Our Industry Experience & Global Business Record

Export Year
2009-01-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the heat transfer capacity range?
The heat transfer capacity ranges from 350 to 1500kW.
Is the monitoring protocol customizable?
Yes, special format monitoring protocols can be customized according to customer requirements.
What materials are used for corrosion resistance?
The system is made with 304 stainless steel and above to ensure long service life.
Does the system support flexible expansion?
Yes, it features a modular design for flexible expansion according to demand.
What is the warranty period?
The product comes with a one-year warranty.
What is the lead time for delivery?
Lead time is one month during off-peak season and 1-3 months during peak season.
What communication protocols are supported?
It supports standard Modbus TCP protocol with comprehensive detection and alarm functions.
Is the system pre-installed?
Yes, the CDU is pre-installed and debugged at the factory.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now