Data Center Cooling Cdu Manufacturers

Shanghai Venttech Refrigeration Equipment Co., Ltd.
  • Audited Supplier
  • 10 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Wide Heat Transfer Range: Customizable capacity from 20 to 1500kW to meet diverse cooling needs.
  • Flexible Installation Options: Available in Rack Mounted and Floor Standing configurations.
  • Customizable Media Compatibility: Supports Softened Water, Ethylene Glycol, Deionized Water, and Propylene Glycol.
  • Intelligent Control System: Features 10-inch touch screen with multi-level authority and auto-protection.
  • High-Efficiency Variable Frequency Pump: Optional dual backup pumps ensure efficient flow and system stability.
  • Corrosion-Resistant Construction: Built with 304 stainless steel and above for long service life.
  • Modular Design: Allows flexible expansion according to specific demand requirements.
  • Comprehensive Monitoring: Tracks temperature, flow, pressure, and optional conductivity, turbidity, and pH.

Product Images of Data Center Cooling Cdu Manufacturers

Data Center Cooling Cdu Manufacturers
Data Center Cooling Cdu Manufacturers pictures & photos
Data Center Cooling Cdu Manufacturers
Data Center Cooling Cdu Manufacturers pictures & photos
Data Center Cooling Cdu Manufacturers
Data Center Cooling Cdu Manufacturers pictures & photos
Data Center Cooling Cdu Manufacturers
Data Center Cooling Cdu Manufacturers pictures & photos
Data Center Cooling Cdu Manufacturers
Data Center Cooling Cdu Manufacturers pictures & photos
Data Center Cooling Cdu Manufacturers
Data Center Cooling Cdu Manufacturers pictures & photos
Data Center Cooling Cdu Manufacturers
  • Data Center Cooling Cdu Manufacturers
  • Data Center Cooling Cdu Manufacturers
    Data Center Cooling Cdu Manufacturers
  • Data Center Cooling Cdu Manufacturers
    Data Center Cooling Cdu Manufacturers
  • Data Center Cooling Cdu Manufacturers
    Data Center Cooling Cdu Manufacturers
  • Data Center Cooling Cdu Manufacturers
    Data Center Cooling Cdu Manufacturers
  • Data Center Cooling Cdu Manufacturers
    Data Center Cooling Cdu Manufacturers
  • Data Center Cooling Cdu Manufacturers
    Data Center Cooling Cdu Manufacturers

Find Similar Products

Product Description

Data Center Cooling Cdu Manufacturers
Product Description

Introduction
    The Coolant Distribution Unit (CDU) is the core component of the water cooling system, responsible for efficiently distributing the coolant to meet various cooling needs. By integrating auxiliary monitoring and support devices, the CDU ensures stable operation of the system.
    It is mainly used for heat exchange control in liquid cooling systems, incorporating secondary side variable frequency circulating pumps, plate heat exchangers, electric control valves, temperature sensors, pressure sensors, filters, expansion tanks, flow meters, and online replenishment functions. The CDU is pre-installed and debugged at the factory, reducing on-site installation and commissioning work.


Performance Range

· Heat Transfer Capacity:350~1500kW


Features
· 10-inch Touch Screen: Multi-level authority control, easy to operate.
· Modular Design: Flexible expansion according to demand.
· High-Efficiency Variable Frequency Pump (Optional): Dual backup pumps automatically adjust flow rate, ensuring efficient operation.
· Dual Power Supply Backup (Optional): Enhances system reliability.
· Corrosion-Resistant Materials: Made with 304 stainless steel and above, ensuring long service life.
· Intelligent Control System: Includes temperature monitoring, secondary side temperature control, flow and differential pressure control, anti-condensation protection, and optional monitoring for conductivity, water turbidity, water hardness, and pH value.
· Ultra-Quiet Motor: Low noise and long service life, suitable for quiet environments.
· Standard Communication Protocol: Supports Modbus TCP, with comprehensive detection, alarm, and protection functions. Setup parameters are automatically protected, and operational parameters and alarm records are retained after power failure.
· Customizable Monitoring Protocol: Special format monitoring protocols can be customized according to customer requirements.
· Secondary Side Filtration Precision: Ultra-wide design range of 25~100μm, meeting various application needs.

Our Advantages
    With Venttk's innovative design, the CDU optimizes the performance and reliability of the water cooling system. It features six channels that connect the main circuit to the secondary water distributor of the water-cooled cabinet, reducing installation and production errors with the use of chucks and rubber hoses.
    Venttk's CDU incorporates a multi-stage centrifugal pump for industrial water circulation, ensuring efficient and reliable coolant flow. An integrated expansion tank compensates for temperature fluctuations, maintaining stable pressure levels and ensuring reliable system operation.
    To prevent issues such as oxidation corrosion, poor circulation, and cavitation of the circulation pump, the CDU includes an automatic air vent valve on the top of the makeup water tank/main pipeline, which promptly eliminates non-condensable gases from the system. 
    Additionally, the CDU is equipped with a 150μm filter in the main path to protect the quality of the coolant, ensuring the reliable and stable operation of the entire system.
    Choose Venttk's Coolant Distribution Unit (CDU) for a more efficient and reliable water cooling system.
Data Center Cooling Cdu Manufacturers
 
Product Parameters
Model VTCDU020W VTCDU030W VTCDU040W VTCDU050W VTCDU060W VTCDU070W VTCDU080W
supply power 220V 1Ph 50Hz
Unit performance parameters
Primary side temp.

35/42 ºC,

Secondary side temp.
40/47
ºC
cooling capacity-kW 21.1  32.2  41.3  53.2  62.5  70.6  82.1 
Secondary side flow rate-m3/h 2.58  3.94  5.06  6.51  7.65  8.64  10.05 
Secondary side pressure drop-kPa 30.7  44.1  62.9  41.4  50.9  62.0  74.7 
Primary side flow rate-m3/h 2.58  3.94  5.06  6.51  7.65  8.64  10.05 
Primary side pressure drop-
kPa
41.2  55.3  74.9  54.5  65.3  78.0  92.5 
Rated power-kW 0.46  0.59  0.73  0.83  0.91  1.00  1.13 
FLA-A 4.26  4.26  4.26  5.97  5.97  5.97  8.81 
Primary side medium Softened water,ethylene glycol solution
Secondary side medium Deionized water,ethylene glycol solution,propylene glycol solution
Primary side pipeline DN32 DN32 DN32 DN40 DN40 DN40 DN40
Secondary side pipeline DN32 DN32 DN32 DN40 DN40 DN40 DN40
Interface type
Chuck

interface

Chuck

interface

Chuck

interface

Chuck

interface

Chuck

interface

Chuck

interface

Chuck

interface
Width    -mm 600  600  600  600  600  600  600 
Deep-mm 1200  1200  1200  1200  1200  1200  1200 
Height-mm 2000  2000  2000  2000  2000  2000  2000 
Weight-kg 200  200  200  220  220  220  220 

Factory

Data Center Cooling Cdu Manufacturers
Data Center Cooling Cdu Manufacturers
 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2241984". Items marked "verified" are certified.

Watch Video
Watch Video
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.

About Our Factory & Business Background

Address
Room 1801, Building 1, Lane 1100, Lanzhou Road, Yangpu District, Shanghai, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, EXW, Others
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month
Nearest Port
SHANGHAI, GUANGZHOU, QINGDAO

Our Production Capability & Technical Expertise

Main Products
Air Conditioning, Refrigeration Unit, Chiller, Condenser Units, Plate Heat Exchanger, Dry Cooler, Air Cooler, Condenser, Evaporator, Shell and Tube Heat Exchanger

Our Industry Experience & Global Business Record

Export Year
2009-01-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the heat transfer capacity range?
The CDU offers a customizable heat transfer range from 20kW to 1500kW.
What installation types are available?
The unit is available in both Rack Mounted and Floor Standing configurations.
What fluids can be used as the primary and secondary media?
Primary side supports softened water and ethylene glycol solution; secondary side supports deionized water, ethylene glycol, and propylene glycol.
Does the system include intelligent control features?
Yes, it features a 10-inch touch screen, multi-level authority control, and automatic parameter protection.
Is the pump system designed for reliability?
Yes, it includes optional high-efficiency variable frequency pumps with dual backup capabilities.
What materials are used for corrosion resistance?
The unit is constructed with 304 stainless steel and above to ensure durability.
Can the monitoring protocol be customized?
Yes, special format monitoring protocols can be customized according to customer requirements.
What is the filtration precision range?
The secondary side filtration precision has a wide design range of 25 to 100 micrometers.