Heat-Duct Heat Recovery Rooftop Air Conditioner Unit

Product Details
Customization: Available
Type: Air Conditioner
Air Tube Material: Galvanized Sheet
Still deciding? Get samples of US$ 15000/Piece
Request Sample
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
  • Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
  • Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
  • Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
  • Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
  • Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
Find Similar Products

Basic Info.

Model NO.
FLWKR43Z(E)
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Mechanical Engineering
Mounting
Floor Standing
Lifetime
15~20 years
Certification
RoHS, ISO, CE
Condition
New
Product Name
Heat-Duct Heat Recovery Rooftop Air Conditioner Un
Cooling Capacity
108kw
Heating Capacity
111kw
Supply Air Volume
23000CMH
Esp
400PA
Fan Motor Power
11kw
Power Supply
380V-3pH-50Hz
Compressor Type
Closed Scroll Type
Refrigerant
R22/R407c/R410A
Control Type
Thermal Expansion Valve
Transport Package
Wrap Film/Pallet
Specification
refrigerator unit
Trademark
VENTTK/OEM
Origin
China
HS Code
841581209
Production Capacity
100units/Month

Product Description

             Heat-duct heat recovery Rooftop air conditioner unit
BRIEF INTRODUCTION AND FEATURES
Rooftop air-conditioning unit is DX air-cooled type, combined of the refrigeration system, control systems and different air handling sections,
achieving cooling, heating, dehumidification, humidification, air purification, sterilization and other functions.Complete with a wide cooling
capacity range, no need cooling water system, omit the dedicated room and complex cooling towers, water pumps and the corresponding
pipelines, control device. Unit usually mounted on the roof or other outdoor location, don't need dedicated room, which greatly save the cost
of civil work. Besides, It's easy to install--- only to connect the duct then power on to run, which also save the cost of maintenance.

GENERAL INTRODUCTION
VENTTK® is one of Chinese largest manufacturers of HVAC system products.
The company has been supplying units to the commercial, industrial markets.
Like Singapore, America, Vietnam, UAE, Australia, Korea, Russia, Iran, Bahrain, Kazakhstan etc. more than 15 years.
Our mission is to provide the most competitively priced, reliable and efficient air conditioning equipment available to the international market.
Our FLWKR series units are single packaged units which are factory assembled,tested and shipped complete with compressor,evaporator and condenser coils, fans and controls.
These packages are designed for outdoor installation mainly, or on ground level, and as well as indoor installation as optional with centrifugal condensate fan.
They may be used for cooling only or heat pump, and efficient both when heating and cooling.
If cooling only model, you may add the Electric heater for heating backup.
The units are ideal for residential, commercial and industrial applications.
Quality design and construction make Shenglin air-cooled rooftop package units with hermetic scroll compressors the preferred applications and easy installation and maintenance.
 
Specifications of Models:
Heat-duct heat recovery low humidity Rooftop unit
Model   FLWKXHR-   40 50 60 80 90 110 120 150 180 200
Specification Cooling capacity 1* kW 59.5 73.1 89.3 117.3 134 161.7 178 201 226 253
Coil cooling capacity KW 56.2 56.5 69.3 90 104 125 138 172 206 240
Heat-duct
recovery
enthalpy drop KJ/kg 10 10 10 10 10 10 10 10 10 10
 Recycling
cooling
KW 13.3 16.6 20 26.6 30 36.7 40 50 60 50
Heat-pipe reheating KW 13.3 16.6 20 26.6 30 36.7 40 50 60 72
Heating capacity 2* KW 26.4 32.3 39.6 51.5 57.2 71.5 78.5 98.4 103.1 114.4
Fresh air volume 3* CMH 4000 5000 6000 8000 9000 11000 12000 15000 18000 20000
ESP 3* Pa 200 250 250 300 300 350 350 400 400 500
Noise 4* dB
(A)
59 61 62 63 65 66 68 70 72 73
Wet-film humidity5* Kg/h 13 15 18 25 32 40 40 50 50 50
Power supply      3N-380V-50Hz      
Total capacity 6* Kw 17.7 19.6 24.4 33.4 39.3 44.5 50.5 7. 79.8 88.2
Compressor qty 2 2 2 2 2 4 4 4 4 4
Refrigerantor Type R22/R407C/R410A
Refrigerant control external equalizer TXV(thermostaice expansion valve)/electronic expansion valve(EXV)
Dimensions L mm 2700 2800 3400 3400 6400 6400 6700 6700 7200 7200
W mm 1800 2200 2200 2200 2300 2300 2300 2300 2300 2300
H mm 1520 1700 1900 1900 2200 2200 2200 2200 2200 2300
Weight kg 830 870 1250 1450 1550 1800 2050 2600 2890 3160
 
 
Heat-duct heat recovery low humidity Rooftop unit
Model   GT-WKXHR-   40 50 60 80 90 110 120 150 180 200
Specification Cooling capacity 1* kW 59.5 73.1 89.3 117.3 134 161.7 178 201 226 253
Coil cooling capacity KW 56.2 56.5 69.3 90 104 125 138 172 206 240
Heat-duct
recovery
enthalpy drop KJ/kg 10 10 10 10 10 10 10 10 10 10
 Recycling
cooling
KW 13.3 16.6 20 26.6 30 36.7 40 50 60 50
Heat-pipe reheating KW 13.3 16.6 20 26.6 30 36.7 40 50 60 72
Heating capacity 2* KW 26.4 32.3 39.6 51.5 57.2 71.5 78.5 98.4 103.1 114.4
Fresh air volume 3* CMH 4000 5000 6000 8000 9000 11000 12000 15000 18000 20000
ESP 3* Pa 200 250 250 300 300 350 350 400 400 500
Noise 4* dB
(A)
59 61 62 63 65 66 68 70 72 73
Wet-film humidity5* Kg/h 13 15 18 25 32 40 40 50 50 50
Power supply      3N-380V-50Hz      
Total capacity 6* Kw 17.7 19.6 24.4 33.4 39.3 44.5 50.5 7. 79.8 88.2
Compressor qty 2 2 2 2 2 4 4 4 4 4
Refrigerantor Type R22/R407C/R410A
Refrigerant control external equalizer TXV(thermostaice expansion valve)/electronic expansion valve(EXV)
Dimensions L mm 2700 2800 3400 3400 6400 6400 6700 6700 7200 7200
W mm 1800 2200 2200 2200 2300 2300 2300 2300 2300 2300
H mm 1520 1700 1900 1900 2200 2200 2200 2200 2200 2300
Weight kg 830 870 1250 1450 1550 1800 2050 2600 2890 3160
 
 


Brand configurations sheet:
Special OEM requirements:
All PU panels of 1.0mm thick GI sheet with hard top powder coating rough surface (NOT SMOOTH TYPE)
Copper tube aluminum fins(golden epoxy resin) with SS316L frame---Strong anti-corrosion

Photos show:
Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
Heat-Duct Heat Recovery Rooftop Air Conditioner Unit
Heat-Duct Heat Recovery Rooftop Air Conditioner Unit








 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier