HVAC System Fiberglass Reinforced Plastic Water Cooling Tower

Product Details
Customization: Available
Cooling Method: Counter Flow
Ventilation Mode: Mixing Ventilation
Still deciding? Get samples of US$ 600/Piece
Request Sample
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • HVAC System Fiberglass Reinforced Plastic Water Cooling Tower
  • HVAC System Fiberglass Reinforced Plastic Water Cooling Tower
  • HVAC System Fiberglass Reinforced Plastic Water Cooling Tower
  • HVAC System Fiberglass Reinforced Plastic Water Cooling Tower
  • HVAC System Fiberglass Reinforced Plastic Water Cooling Tower
  • HVAC System Fiberglass Reinforced Plastic Water Cooling Tower
Find Similar Products

Basic Info.

Model NO.
D5-005-6X350
Material
FRP
Air Contact Form
Wet and Dry
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Low
Application Fields
Air Conditioning
Certification
RoHS, ISO, CE, CCC
Condition
New
Coil Material
SS304/SS316/Copper/Hot Dipped Galvanised Steel
Colour
Blue Green Black Grey
Casing Material
Hot Dipped Galvanised, Stainless Steel
Fans Diameter
700-6000mmm
Fan Type
Axial Flow
Voltage
380-415V
Application
Water Cooling Chiller
Shape
Round, Square
Cooling Capacity
50~300rt
Transport Package
Wrapping Film
Specification
Customized
Trademark
Venttech
Origin
China(Mainland)
HS Code
8418619000
Production Capacity
50000units / Month

Product Description

HVAC System Fiberglass Reinforced Plastic Water Cooling Tower
Cooling Tower

WORKING PRINCIPLE

The hot water is pumped through the water pump to pressurize the standby ring water into the cooling water seeding system.Dry the wine evenly on the filler through holes in the seeding pipe

Under the action of the fan, the air enters into the tower from the bottom into the air network to exchange hot water with air. Drop into the chassis and run through the water pump to the heat source for recycling

FEATURES
1. optimization of structure modelling shape size is small high and low igh weight, and four weeks of th
wind, less restricted by decorate venues.
2 the tower body USES the high strength of FR composite material product an, antiaging, corrosion
resistance, ne deformation not faded,
3. all mctal parts manufacturcd thickened just materia and galvanized or painted anticorrosive
4. the water tower adopts the automatic rotating sprinkler, can evenly spray the water to the every corner of
the packing, corrosion resistant, non clogging, high efficiency

MODEL

OVERAII DIMENSION

FIOW RATE
(m3/h)

FAN
(mm)

MOTOR
(hp)

WEIGHT (kg)



NOISE(dB)

L

W

H

H1

H2

NET

RUNNING

LYR-100L/S

1790

3300

3700

2300

700

100

1470

2

995

1610

58.5

LYR-125L/S

2360

3600

3700

2300

700

125

1800

5

1100

2620

59.5

LYR-150L/S

2650

3900

3700

2300

700

150

2100

5

1230

2830

60.5

LYR-175L/S

2650

3900

3700

2300

700

175

2100

7.5

1350

3150

60.5

LYR-200L/S

3090

4300

3700

2300

700

200

2400

7.5

1490

3580

61.5

LYR-225L/S

2900

4990

4080

2680

700

225

2400

7.5

1650

3470

61.5

LYR-250L/S

3150

4990

4080

2680

700

250

2400

10

2320

4520

62.0

LYR-300L/S

3500

5590

4080

2680

700

300

3000

15

2520

5580

62.5

LYR-350L/S

3600

5590

4080

2680

700

350

3000

15

2790

5920

63.0

LYR-400L/S

3840

5930

4230

2680

850

400

3330

15

3190

6630

63.5

LYR-450L/S

4090

5930

4230

2680

850

450

3330

20

3600

7290

63.8

LYR-500L/S

4350

6080

4850

3300

850

500

3330

20

4200

8150

64.2

LYR-600L/S

4650

6400

4850

3300

850

600

3700

25

4620

8960

65.0

LYR-700L/S

4950

6400

5450

3900

850

700

3700

30

5040

9610

66.5

LYR-800L/S

5250

6900

5500

3900

900

800

4200

30

5620

10710

67.0


HVAC System Fiberglass Reinforced Plastic Water Cooling Tower
Characteristics of closed-type cooling tower parts
 

1. Fan

The ventilation system adopts the special aluminum alloy axial fan for cooling tower, the structure design of the front tilting type wind vane, the streamline inlet breeze simple, the wind resistance is small, the air volume is big, the noise is low, the performance is good, the efficiency is high. No belt drive structure, reducing the transmission components, and the use of fully enclosed self-cooling low-noise cooling tower dedicated motor, with small size, light weight, good starting performance, reliable operation, durable and so on.
 

2. Spray system

The use of closed-type cooling tower dedicated pump, its large flow, low head, high efficiency, low noise, small power, evaporative condenser dedicated pump, the implementation of the standard according to SC4210 implementation. Pump motor voltage 380V, protection class IP55, insulation Class F class.
 

3. Fille

The special design of the PNC Bee-type cross-flow, shortcut to the wind structure, so that the air can quickly take away the heat in the water, a unique filler flow, so that the water flow in the filler surface can form a large area of the flow of water film, prolong the cooling time of the water in the filler, improve the water cooling effect. It has the advantages of small wind resistance coefficient, anti-aging, not easy deformation, etc.

4.  Water distribution System

The use of closed-type cooling tower dedicated pump, its high flow, low head effect, low noise, small power, evaporative condenser dedicated pump, the implementation of the standard according to JS-C4210 implementation. Pump motor voltage 380V, protection class 1p55, insulation class F class

5. Circulatory system

Circulating water pump using closed cooling tower dedicated pipe pump, performance stable low sound, motor protection class P5 insulation grade lower, circulating water tank using SUS304 material stainless steel plate, stamping molding, beautiful appearance, strong pressure resistance

HVAC System Fiberglass Reinforced Plastic Water Cooling Tower

Cooling tower applications
Purpose

For medium frequency, high frequency power supply cooling
For medium-frequency quenching workpiece, if quenching liquid cooling
For vacuum heating, vacuum sintering, vacuum welding, vacuum melting furnace
For cooling of air compressors
For central air Conditioning
For cooling of water-cooled screw machine and plate exchange
For screw machines and other equipment

Other Application Industries
Heat pump Generator set Glass melting cellar Boiler steam condensation Power plant
Chemical Oil and beer Silicon industry Food Cold storage
China mobile signal switch Heat exchanger cooling Injection moulding machine  
CNG gas filling station Oil extrusion machine Pharmaceutical factory  

HVAC System Fiberglass Reinforced Plastic Water Cooling Tower
HVAC System Fiberglass Reinforced Plastic Water Cooling Tower

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier