Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding

Product Details
Customization: Available
After-sales Service: One Year
Warranty: One Year
Still deciding? Get samples of US$ 2000/Piece
Request Sample
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding
  • Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding
  • Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding
  • Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding
  • Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding
  • Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding
Find Similar Products

Basic Info.

Model NO.
LYR-300L/S
Ventilation Mode
Mixing Ventilation
Material
FRP
Air Contact Form
Wet and Dry
Air Contact Way
Open
Tower Shape
Round
Noise Level
Low
Application Fields
Industrial
Certification
RoHS, ISO
Condition
New
Coil Material
SS304/SS316/Copper/Hot Dipped Galvanised Steel
Application
Water Cooling Chiller
Shape
Round, Square
Casing Material
Hot Dipped Galvanised, Stainless Steel
Cooling Capacity
50~300rt
Fans Diameter
700-6000mm
Transport Package
Wrap Film Packaging
Specification
See parameters
Trademark
Venttech
Origin
Shanghai
HS Code
8418612090
Production Capacity
50000PCS/Year

Product Description

Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding
We manufacturing central air conditioners like roof-top air conditioners, precision air conditioners, water chillers, and air handling units.

As we make coils by ourselves, so we also manufacturing condensers, evaporators, and dry coolers.

Rooftop air conditioners are easy to be installed and maintained. As they are installed on the top roof, so they will not spare the room space. They are weatherproof and have high efficiency.

Precision air conditioners can control the temperature in ±1ºC and humidity in ±5%. It can be used in data centers and telecom base stations. Most parts are the world-famous brand.

Condensers and evaporators can be widely used in air conditioners, heat pumps, fan coils, air handling units, drinking machines, ice makers, dehumidifiers, laser machines, welding machines, and other areas. We can not only manufacture copper pipe condensers and evaporators but also manufacture stainless steel pipe and aluminum pipe condensers and evaporators.

Dry coolers are mainly for machine cooling, process cooling, oil cooling, free cooling, and cold room cooling.

Our products have been exported to Europe, North America, the Middle East, South Africa, and Southeast Asia for more than 16 years.

We sincerely welcome customers all over the world to visit our company and set up business relationships for mutual benefit.

Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding


WORKING PRINCIPLE
The hot water is pumped through the water pump to pressurize the standby ring water into the cooling water seeding system.Dry the wine evenly on the filler through holes in the seeding pipe
Under the action of the fan, the air enters into the tower from the bottom into the air network to exchange hot water with air. Drop into the chassis and run through the water pump to the heat source for recycling


FEATURES
1. optimization of structure modelling shape size is small high and low igh weight, and four weeks of th
wind, less restricted by decorate venues.
2 the tower body USES the high strength of FR composite material product an, antiaging, corrosion
resistance, ne deformation not faded,
3. all mctal parts manufacturcd thickened just materia and galvanized or painted anticorrosive
4. the water tower adopts the automatic rotating sprinkler, can evenly spray the water to the every corner of
the packing, corrosion resistant, non clogging, high efficiency

 

MODEL OVERAII DIMENSION FIOW RATE
(m3/h)
FAN
(mm)
MOTOR
(hp)
WEIGHT (kg)

NOISE(dB)
L W H H1 H2 NET RUNNING
LYR-100L/S 1790 3300 3700 2300 700 100 1470 2 995 1610 58.5
LYR-125L/S 2360 3600 3700 2300 700 125 1800 5 1100 2620 59.5
LYR-150L/S 2650 3900 3700 2300 700 150 2100 5 1230 2830 60.5
LYR-175L/S 2650 3900 3700 2300 700 175 2100 7.5 1350 3150 60.5
LYR-200L/S 3090 4300 3700 2300 700 200 2400 7.5 1490 3580 61.5
LYR-225L/S 2900 4990 4080 2680 700 225 2400 7.5 1650 3470 61.5
LYR-250L/S 3150 4990 4080 2680 700 250 2400 10 2320 4520 62.0
LYR-300L/S 3500 5590 4080 2680 700 300 3000 15 2520 5580 62.5
LYR-350L/S 3600 5590 4080 2680 700 350 3000 15 2790 5920 63.0
LYR-400L/S 3840 5930 4230 2680 850 400 3330 15 3190 6630 63.5
LYR-450L/S 4090 5930 4230 2680 850 450 3330 20 3600 7290 63.8
LYR-500L/S 4350 6080 4850 3300 850 500 3330 20 4200 8150 64.2
LYR-600L/S 4650 6400 4850 3300 850 600 3700 25 4620 8960 65.0
LYR-700L/S 4950 6400 5450 3900 850 700 3700 30 5040 9610 66.5
LYR-800L/S 5250 6900 5500 3900 900 800 4200 30 5620 10710 67.0

Closed Water Steel Frame Cooling Tower Price for Plastic Injection MoldingCharacteristics of closed-type cooling tower parts
1. Fan
The ventilation system adopts the special aluminum alloy axial fan for cooling tower, the structure design of the front tilting type wind vane, the streamline inlet breeze simple, the wind resistance is small, the air volume is big, the noise is low, the performance is good, the efficiency is high. No belt drive structure, reducing the transmission components, and the use of fully enclosed self-cooling low-noise cooling tower dedicated motor, with small size, light weight, good starting performance, reliable operation, durable and so on.


2. Spray system
The use of closed-type cooling tower dedicated pump, its large flow, low head, high efficiency, low noise, small power, evaporative condenser dedicated pump, the implementation of the standard according to SC4210 implementation. Pump motor voltage 380V, protection class IP55, insulation Class F class.

3. Fille
The special design of the PNC Bee-type cross-flow, shortcut to the wind structure, so that the air can quickly take away the heat in the water, a unique filler flow, so that the water flow in the filler surface can form a large area of the flow of water film, prolong the cooling time of the water in the filler, improve the water cooling effect. It has the advantages of small wind resistance coefficient, anti-aging, not easy deformation, etc.

4. Water distribution System
The use of closed-type cooling tower dedicated pump, its high flow, low head effect, low noise, small power, evaporative condenser dedicated pump, the implementation of the standard according to JS-C4210 implementation. Pump motor voltage 380V, protection class 1p55, insulation class F class

5. Circulatory system
Circulating water pump using closed cooling tower dedicated pipe pump, performance stable low sound, motor protection class P5 insulation grade lower, circulating water tank using SUS304 material stainless steel plate, stamping molding, beautiful appearance, strong pressure resistance

Closed Water Steel Frame Cooling Tower Price for Plastic Injection MoldingCooling tower applications
Purpose
For medium frequency, high frequency power supply cooling
For medium-frequency quenching workpiece, if quenching liquid cooling
For vacuum heating, vacuum sintering, vacuum welding, vacuum melting furnace
For cooling of air compressors
For central air Conditioning
For cooling of water-cooled screw machine and plate exchange
For screw machines and other equipment

 
Other Application Industries
Heat pump Generator set Glass melting cellar Boiler steam condensation Power plant
Chemical Oil and beer Silicon industry Food Cold storage
China mobile signal switch Heat exchanger cooling Injection moulding machine  
CNG gas filling station Oil extrusion machine Pharmaceutical factory  
Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding
Closed Water Steel Frame Cooling Tower Price for Plastic Injection Molding

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier