Single Compressor Water Cooled Screw Flooded Chiller

Shanghai Venttech Refrigeration Equipment Co., Ltd.
  • Audited Supplier
  • 10 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • High-Efficiency Screw Compressor: Features 20-30% higher efficiency with patented 5-to-6 rotor profile and world-famous brand technology.
  • Extended Bearing Life: Equipped with 11 bearings and balance piston, extending life 2.5 to 3.5 times compared to traditional designs.
  • Flexible Capacity Control: Supports four-step, three-step, and no-step control systems for optimal energy regulation.
  • Multiple Refrigerant Options: Available with R22, R134A, R407C, and other environment-friendly refrigerants.
  • Advanced Oil Pressing System: Built-in system ensures optimal lubricity without the need for an external oil pump.
  • High-Efficiency Oil Separator: Double filtration design maximizes heat exchanger performance and system efficiency.
  • Low Noise and Vibration: Designed for efficient operation with minimal noise and vibration levels.
  • Comprehensive Safety Protection: Includes over-temperature, over-current, pressure, flow switch, and phase sequence protections.

Product Images of Single Compressor Water Cooled Screw Flooded Chiller

Single Compressor Water Cooled Screw Flooded Chiller
Single Compressor Water Cooled Screw Flooded Chiller pictures & photos
Single Compressor Water Cooled Screw Flooded Chiller
  • Single Compressor Water Cooled Screw Flooded Chiller
  • Single Compressor Water Cooled Screw Flooded Chiller
    Single Compressor Water Cooled Screw Flooded Chiller

Find Similar Products

Product Description

         Single compressor water cooled screw flooded chiller

Features
1.World famous brand new type and high-efficient screw-rotor compressor, with efficiency 20%~30% higher than those common ones. It has obtained several patents of Europe and America countries and passed the international quality certification of ISO9001.
2.High efficiency 5-to-6 rotor profile patent.
3.Capacity control apply to four-step (100%-75%-50%-25%),three-step (100%-66%-33%) and no step control system.
4.With 11 bearings and a balance piston against axial thrust. This extends longer bearings life 2.5 to 3.5 times than traditional design.
5.Designed with efficient silicon steel and special slots , and equipped with the inside and outside all around design to cool the flow channel so to ensure maximum efficiency of the compressor motor under any load.
6.Built-in oil pressing system ensure compressor maintaining the optimal lubricity without oil pump.
7.High efficiency double filtration oil separator ensures maxinum heat exchanger.
8.Efficient, low noise and small vibration.
9.Various options of refrigerants, R22, environment-friendly R134A, R407C etc.
10.All-wave compressor volume ratio(Vi=2.2/2.6/3.0/3.5) for selection to avoid the extra energy consumption caused by over or under compression.

 
Model list
Model  Item 040WSH 050WSH 060WSH 075WSH 085WSH 100WSH 120WSH
Nominal cooling
capacity
kcal/h 103888 130204 152564 212420 241660 276060 342280
kw 120.8 151.4 177.4 247 281 321 398
Total input power kw 30.9 37.9 43.3 56.8 65 74 90.3
Max.Running current A 71 84 128 123 140 160 195
Power   3PH-380V-50HZ(200V/220V/415V 50HZ/60HZ)
Refrigerant Type   R22
Refrigerant
charge
kg 22 27 33 42 48 55 68
Control method   thermostatic expansion valve
Compressor Type   Semi-hermetic screw
Power kw 30.9 37.9 43.3 56.8 65 74 90.3
Start-up mode   Y-△
Capacity control % 0-25-50-75-100
Evaporator Type   Shell and Tube
Chilled fluid flow m3/h 20.7 26.0 30.4 42.3 48.2 55.0 68.2
Inlet/outlet
pipe diameter
Inch 3" 3" 3" 3" 4" 4" 4"
Condenser Type   Shell and Tube  
Cooling water flow m3/h 26.0 32.5 37.8 52.1 59.3 67.7 83.7    
Inlet/outlet pipe caliber Inch 3" 3" 3" 3" 4" 4" 4"    
Safety protection Compressor over temperature,over current,high and low pressure,over temperature,flow switch,
phase sequence,phase-missing,exhaust Overheating,anti-freezing.
 
Dimension Length mm 1960 2130 2450 2450 2750 2750 2750    
Width mm 855 855 985 985 1050 1050 1050    
Height mm 1540 1540 1600 1600 1600 1600 1730    
Net weight   820 950 1120 1300 1560 1720 2030    
Running weight   970 1060 1270 1480 1780 1960 2250    
                     


1.Transportation of unit
(1). The chiller is packed in standard wooden box. We suggest hoisting if conditions warrant it. The forklift can be used during ground transportation. If the hoisting is made after the removal of packaging, pay attention not to put too much pressure on the chiller box. If necessary with the supporting rod to hoist.
(2). The units with wheel can be rolled on the ground and the units must keep balance
(3). Whatever way to transport, it must be carefully not to sway over not to collide so as not to damage
the equipment or endanger the safety of people.
★Not to use the forklift to transport the units after the package removed!
2.Installation of unit
(1).How to choose the installation location
Unit suitable for installation in the ambient temperature of -10~43 degrees, relative humidity of not more than 80% of the rain-proof shelter, or with the external environment has good ventilation conditions of indoor. In the wind direction is not less than 2meters of space, in a side condenser inlet wind direction should have 1.5~2meters of space. Units to be placed in no less than 20cm level solid concrete foundation, DLP-10AS and larger units with damping device, using the anchor bolt. Around the unit should have a working space, to facilitate the operation, inspection and maintenance.
Single Compressor Water Cooled Screw Flooded Chiller


Single Compressor Water Cooled Screw Flooded Chiller
Single Compressor Water Cooled Screw Flooded Chiller
Single Compressor Water Cooled Screw Flooded Chiller
Single Compressor Water Cooled Screw Flooded Chiller
 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2241984". Items marked "verified" are certified.

Watch Video
Watch Video
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.
Shanghai Venttech Refrigeration Equipment Co., Ltd.

About Our Factory & Business Background

Address
Room 1801, Building 1, Lane 1100, Lanzhou Road, Yangpu District, Shanghai, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CFR, CIF, DAT, EXW, Others
Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month
Nearest Port
SHANGHAI, GUANGZHOU, QINGDAO

Our Production Capability & Technical Expertise

Main Products
Air Conditioning, Refrigeration Unit, Chiller, Condenser Units, Plate Heat Exchanger, Dry Cooler, Air Cooler, Condenser, Evaporator, Shell and Tube Heat Exchanger

Our Industry Experience & Global Business Record

Export Year
2009-01-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What refrigerants are available for this chiller?
Various options are available including R22, environment-friendly R134A, and R407C.
How does the capacity control system work?
It supports four-step (100%-75%-50%-25%), three-step (100%-66%-33%), and no-step control systems.
What is the expected bearing life compared to traditional designs?
The bearing life is extended 2.5 to 3.5 times due to the 11 bearings and balance piston design.
What are the installation environmental requirements?
Suitable for ambient temperatures of -10 to 43 degrees Celsius with relative humidity not exceeding 80%.
How is the unit transported and handled?
Packed in standard wooden boxes; forklifts can be used before packaging removal, but not after.
What safety protections are included?
Includes protection against over-temperature, over-current, high/low pressure, flow switch issues, and phase sequence errors.
What is the efficiency improvement of the compressor?
The compressor offers 20% to 30% higher efficiency than common ones with patented rotor profiles.
Does the chiller require an oil pump?
No, the built-in oil pressing system ensures optimal lubricity without an external oil pump.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now