Precision Air Conditioner, Computer Room HVAC, It Room Cooling manufacturer / supplier in China, offering Inrow Cooling Unit for Server Rooms & Data Center, Ss304L Floorstanding Flatbed Dry Air Coolers, R410A Packaged Rooftop Air Conditioner Unit and so on.

(/ )

Supplier Homepage Product air conditioner precision air conditioner Inrow Cooling Unit for Server Rooms & Data Center

Inrow Cooling Unit for Server Rooms & Data Center

FOB Price: US $1,088 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1,088/ Piece
Get Latest Price
Production Capacity: 1500units Per Month
Transport Package: Export Packaging
Payment Terms: T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: GT-HFM-12
  • Cooling Water: Chilled Water
  • Fans Species: Single-speed Fan
  • Application Fields: Data Center Cooling 
  • Condition: New
  • Cooling Capacity: 40kw
  • Supply Air: 5800
  • Compressor: Efficient Scroll Closed
  • Condenser: Tube Fin Heat Exchanger
  • Air Filter: Initially Effect Plate Filter
  • Specification: customized
  • HS Code: 8415830000
  • Type: Water-Cooled
  • System Type: Closed System
  • Noise Level: Low
  • Certification: RoHS, ISO
  • Product: Precision Air Conditioner
  • Heating Capacity: 37.1kw
  • Power: 3n-380V-50Hz
  • Evaporator: Tube Fin Heat Exchanger
  • Refrigerant: R22/R407c
  • Trademark: VENTTECH
  • Origin: Shanghai, China(Mainland)
Product Description
Data Center Cooling System Precision Air Conditioner

Features:
1.Cooling capacity: 7.5KW-93.6KW
2.Refrigerant: R22(R407C/R410A)
3.Digital control mode, can reach high accuracy.
4.Keep the dust, oil fog and moisture from entering the internal of the equipments.
5.The structure design makes the installation more flexible. And the unit can be installed perfectly in the side or outside wall of the equipment.
6.Totally solve dust and moisture contamination issues caused by ventilation.
7.Widely used in telecommunications, broadcasting, electricity, automation and other industries out-door cabinet, IDC room cooling needs.
 
GT-HFM series constant temperature and humidity precision air conditioner specification 1
Model GT-HFM-()712151820242730
SpecTotal cooling capacitykW7.512.615.318.621.824.227.531.8
Sensible cooling capacitykW6.911.714.117.420.222.42529.5
Electric heatingkW3669991215
Air volume 2*m3/h18003250410052005400660075009000
Outlet air pressure 2*Pa2525255050757575
Noise 3*dB(A)5454555656565656
Temperature controlºC18~28,±1
 range and accuracy
Humidity control%45~70,±5
range and accuracy
Power3N-380V-50Hz
Input power 4*kW61112.616.817.51923.928.9
Indoor 
unit
Supply 
air fan
typelow noise centrifugal type
capacitykW0.320.550.751.11.11.52.22.2
Electrode 
humidifier
humidification 
volume
kg/h33555888
Electric 
heating
capacitykW3669991215
Evaporator typeInner grooved copper tube and aluminum fin
Air filterprimary efffect plate type filter
DimensionLmm9501200120012001200160016001600
Wmm580680680680680780780780
Hmm18001880188018801880200020002200
Weightkg190230270290300400430510
Outdoor 
unit
Model GT-( )*quantityWL08*1WL12*1WL15*1WL18*1WL20*1WL25*1WL27*1WL30*1
compressortypeTotally enclosed scroll type
quantity11111111
condenser typeInner grooved copper tube and aluminum fin
Condensing
 fan
typeLow noise axial type
capacitykW0.370.370.370.550.550.550.750.75
DimensionLmm800850850980980980980980
Wmm800850850980980980980980
Hmm9801080108010801080108012341234
Weightkg90120150170170205210220
Freon 5*typeR22(R407C/R410A)
control methodOut balance expansion valve
Collecting pipe 6*liquid pipe`s 
diameter
mm9.52
(9.52)
12.7
(9.52)
12.7
(9.52)
15.88 
(12.7)
15.88 
(12.7)
15.88 
(12.7)
15.88 
(12.7)
15.88 
(12.7)
gas pipe`s 
diameter
mm15.88
(12.7)
19.05
(15.88)
19.05 
( 15.88)
22.23 
(19.05)
22.23 
(19.05)
28.6 
(22.23)
28.6 
(22.23)
28.6 
(22.23)

1.Cooling condition: Indoor dry bulb/wet bulb: 24/17C; Outdoor dry bulb/wet bulb: 35/24C.
2.Air volume\static pressure are standard data, it can be designed by client
3.Noise data is measured 3 meters far away from the units
4.The input power means the power consumption under max condtion.
5.If freon is R410A or R407C, please noted it in the order
6.The dimension in the brackets is for R410A`s collecting pipe

Applicable Fields:
1. Mobile base station.
2. Outdoor rooms.
3. Satellite ground station.
4. Paging machine room.
5. Network management center.
6. Small computer room.
7. Small laboratory.
8. Wine cellar, etc
9. server room,computer room
10. workshop, exhibition hall, precision machine manufacture, metering room 
Computer Room satellite ground station
IDF Roompaging machine room
Security Equipment Roomnetwork management center
Data Centersmall computer room
main computer roomsmall laboratory
Mobile base stationwine cellar
outdoor rooms CRAC

 
Product Description:
Constant temperature and humidity air conditioning is a sophisticated environmental control system, according to the requirement of the environment, you can configure different component implementation refrigeration, heating and humidification. Meet the requirements of precision equipment or sensitive to the environment.

Features:
1. Reasonable energy-saving design, than common air conditioning to save 20-30% of the energy consumption
2. There are constant temperature and humidity function, high winds, to meet the needs of professional computer room.
3. Using stable vortex compressor, long service life of the product.
4. Password protection, ultra wide input voltage design.
5. Equipped with standard monitoring interface, the host and the standby machine function on duty by turns.
6. Network management function, configuration standard RS485 monitoring interface, provide standard communication protocol.

 